Table 3 Comparison of the mechanical properties of respiratory measurement using IOS for men and women

From: Impact of obstructive sleep apnea on lung volumes and mechanical properties of the respiratory system in overweight and obese individuals

Parameters

Men (n = 180)

Women (n = 70)

Non-OSA group (n = 83)

OSA group (n = 97)

p-Value

Non-OSA group (n = 35)

OSA group (n = 35)

p-Value

Zrs5, (kPa/L/s)

0.37 ± 0.11

0.45 ± 0.13

<0.001

0.53 ± 0.14

0.61 ± 0.18

0.033

R5, (kPa/L/s)

0.35 ± 0.10

0.43 ± 0.12

<0.001

0.50 ± 0.13

0.57 ± 0.15

0.041

R10,(kPa/L/s)

0.32 ± 0.09

0.38 ± 0.09

<0.001

0.44 ± 0.11

0.47 ± 0.11

0.140

R15,(kPa/L/s)

0.30 ± 0.07

0.34 ± 0.08

<0.001

0.40 ± 0.10

0.42 ± 0.09

0.242

R20,(kPa/L/s)

0.30 ± 0.07

0.35 ± 0.08

<0.001

0.40 ± 0.09

0.42 ± 0.10

0.350

R25,(kPa/L/s)

0.30 ± 0.08

0.36 ± 0.09

<0.001

0.41 ± 0.08

0.42 ± 0.09

0.434

R35,(kPa/L/s)

0.33 ± 0.07

0.39 ± 0.09

<0.001

0.43 ± 0.08

0.45 ± 0.09

0.317

Grs, (L/s/kPa)

2.78 ± 0.64

2.26 ± 0.50

<0.001

1.92 ± 0.45

1.61 ± 0.33

0.002

sGrs, (s−1 · kPa−1)

0.76 ± 0.19

0.68 ± 0.17

0.007

0.68 ± 0.17

0.63 ± 0.17

0.171

Gz, (L/s/kPa)

2.94 ± 0.75

2.40 ± 0.63

<0.001

2.04 ± 0.55

1.76 ± 0.44

0.021

sGz, (s−1 · kPa−1)

0.80 ± 0.22

0.72 ± 0.19

0.031

0.72 ± 0.19

0.69 ± 0.21

0.363

X5,(kPa/L/s)

−0.08 ± 0.05

−0.13 ± 0.08

<0.001

−0.15 ± 0.07

−0.22 ± 0.13

0.008

X10,(kPa/L/s)

−0.03 ± 0.04

−0.05 ± 0.06

<0.001

−0.07 ± 0.06

−0.12 ± 0.09

0.030

X15,(kPa/L/s)

0.00 ± 0.04

−0.02 ± 0.05

<0.001

−0.04 ± 0.06

−0.08 ± 0.08

0.033

X20,(kPa/L/s)

0.03 ± 0.03

0.02 ± 0.04

0.002

0.03 ± 0.18

−0.03 ± 0.06

0.029

X25,(kPa/L/s)

0.07 ± 0.03

0.06 ± 0.04

0.060

0.05 ± 0.04

0.02 ± 0.05

0.027

X35,(kPa/L/s)

0.12 ± 0.04

0.11 ± 0.04

0.646

0.09 ± 0.04

0.09 ± 0.04

0.911

Fres,(Hz)

14.4 ± 4.7

17.7 ± 6.0

<0.001

19.4 ± 7.4

23.5 ± 9.3

0.081

  1. Abbreviations: Zrs5 respiratory system impedance at 5Hz (oscillatory frequency), R5 ~ R35 respiratory system resistance at 5, 10, 15, 20, 25, 35 oscillatory frequencies, X5 ~ X35 respiratory system reactance at 5, 10, 15, 20, 25, 35Hz, Grs respiratory conductance, reciprocal of R0 (total respiratory resistance, namely the resistance origin at the point of zero frequency), sGrs the specific Grs (the ratio of Grs to actual value of FRC), Gz reciprocal of Zrs5, sGz the specific Gz (the ratio of Gz to actual value of FRC), Fres resonant frequency, integrated area of low-frequency reactance from zero line between X5 and resonant frequency; IOS parameters are expressed as mean ± SD. Comparison was made between the two group using Mann–Whitney-Wilcoxon test. A p-value below 0.05 was considered to exist significant difference