Skip to main content

Table 2 Operation and follow-up information of 6 patients

From: Innovative method for Amplatzer device implantation in patients with bronchopleural fistulas

Serial number

Location of BPF

Fistula diameter

AD model

Duration of operation

Completely blocked

Removed drainage tube

Time from closure to extubation

Follow-up time

1

Right lower bronchus

10 mm

22-10-24 mm

10 min

Yes

Yes

3 days

17 months

2

Right lower bronchus

8 mm

16-8-20 mm

15 min

Yes

Yes

3 months

15 months

3

Left main bronchus

10 mm

23-12-27 mm

18 min

Yes

No

NA

NA

4

Upper left bronchus

8 mm

16-8-20 mm

20 min

Yes

Yes

2 months

12 months

5

Right main bronchus

10 mm

22-10-24 mm

22 min

Yes

Follow-up

NA

12 months

6

Right middle and lower bronchi

Several small fistulas

23-12-27 mm

12 min

No

Yesb

NAb

10 months

  1. aAlthough patient No. 3 underwent closure in the ICU with respiratory failure was observed to have a significant reduction in air leakage after AD implantation, he eventually died on the third postoperative day due to complications from severe pneumonia
  2. bPatient No. 6 underwent thoracoscopic flap sealing after closure failure of AD implantation, and his drainage tube was removed one week after surgery