Skip to main content

Table 4 Multiple linear regression analysis of CVP and PEEP

From: High positive end expiratory pressure levels affect hemodynamics in elderly patients with hypertension admitted to the intensive care unit: a prospective cohort study

All subjects

Model1

Model2

Model3

CVP

Beta

0.150

0.152

0.174

P

0.012

0.012

0.004

  1. Model 1: Adjustment for age and gender; Model 2: Adjustment for age, gender, triglyceride, total cholesterol, low density lipoprotein cholesterin, fasting plasma glucose, serum creatinine and uric acid; Model 3: Adjustment for hemoglobin, body temperature, minute ventilation volume and peripheral oxygen saturation on the basis of Model 2