| Symptom |
---|
 | Cough | No cough | Phlegm | No phlegm | Wheeze | No wheeze | Shortness of breath | No shortness of breath |
---|
R5-20 (cmH2O.s/L) | 1.14a | 0.61a | 1.13b | 0.54b | 1.11c | 0.58c | 1.41d | 0.80d |
Ax (cmH2O/L) | 16.7e | 9.04e | 17.0f | 7.56f | 17.1Â g | 7.07Â g | 22.0Â h | 12.0Â h |
X5 (cmH2O.s/L) |  − 1.53i |  − 1.29i |  − 1.54j |  − 1.13j |  − 1.63 k |  − 1.15 k |  − 1.79 l |  − 1.14 l |
- Mean oscillometry values are reported for R5–20, Ax and X5 based on the presence of individual symptoms. R5–20 is a measure of small airway resistance. Ax is a measure of the area under the reactance curve. X5 is a measure of airway elastance. The presence of cough was defined as the presence of a cough on most days in the absence of a cold. The presence of phlegm was defined as the production of phlegm on most days in the absence of a cold. The presence of wheeze was defined as the presence of a wheeze any time in the last 12 months. The presence of shortness of breath was defined as activity limitation due to shortness of breath. P values were generated using a two-tailed t-test. ap = 0.06; bp = 0.03; cp = 0.05; dp = 0.12; ep = 0.07; fp = 0.02; gp = 0.01; hp = 0.13; ip = 0.42; jp = 0.16; kp = 0.15; lp = 0.40. n = 56. Bolded font indicates statistical significance