Skip to main content

Table 4 ROC curve analysis for predicting EID

From: Prediction of exercise-induced desaturation in COPD patients without resting hypoxemia: a retrospective study

Variables

AUC

Cut-off value

Sensitivity

Specificity

P

CAT score

0.727

15

0.753

0.66

 < 0.001

DLCO SB%pred (%)

0.689

50.45

0.889

0.425

0.001

DLCO/VA%pred (%)

0.707

80.90

0.733

0.589

 < 0.001

mean density (HU)

0.671

− 856.46

0.808

0.593

0.033

PD15 (HU)

0.691

− 955.00

0.692

0.704

0.017

emphysema volume (ml)

0.668

338.14

0.689

0.667

0.003

%LAA (%)

0.656

7.63%

0.635

0.667

0.005

  1. ROC Receiver operating characteristic; EID Exercise-induced desatuation; CAT COPD Assessment Test; AUC Area under curve; DLCO SB% pred Lung carbon monoxide diffusion as a percentage of predicted value; DLCO/VA% pred Lung carbon monoxide diffusion per liter of alveolar air volume as a percentage of predicted value; PD15 15th percentile point; %LAA % Low attenuation areas