Skip to main content

Table 4 Diagnostic accuracy for nurse-led anthropometric and oropharyngeal characteristics combined with sleep questionnaire to detect moderate/severe OSA (AHI ≥ 15)

From: The value of nurse-led anthropometric and oropharyngeal measurements combined with STOP-Bang questionnaire in screening for obstructive sleep apnea in patients with acute coronary syndrome: a prospective cohort study

Variables

AUC

Cut-off

Sen-

Spe-

PPV

NPV

PLR

NLR

ESS

0.579

6.00

0.67

0.44

0.57

0.54

1.20

0.72

SBQ

0.684

4.00

0.73

0.51

0.63

0.63

1.52

0.51

SBQ + Micrognathia + WC

0.729

0.49

0.73

0.61

0.68

0.66

1.88

0.44

  1. ESS Epworth sleepiness scale, NLR Negative Likelihood Ratio, NPV negative predictive value, PLR Positive likelihood ratio, PPV positive predictive value, SBQ Stop-bang questionnaire, Sen Sensitivity, Spe Specificity, WC Waist circumference