- Research article
- Open access
- Published:
A prospective observational study to evaluate the effect of social and personality factors on continuous positive airway pressure (CPAP) compliance in obstructive sleep apnoea syndrome
BMC Pulmonary Medicine volume 17, Article number: 56 (2017)
Abstract
Background
Compliance with CPAP treatment for OSAS is not reliably predicted by the severity of symptoms or physiological variables. We examined a range of factors which could be measured before CPAP initiation to look for predictors of compliance.
Methods
This was a prospective cohort-study of CPAP treatment for OSAS, recording; socio-economic status, education, type D personality and clinician’s prediction of compliance.
Results
We recruited 265 subjects, of whom 221 were still using CPAP at 6 months; median age 53 years, M: F, 3.4:1, ESS 15 and pre-treatment ODI 21/h. Median compliance at 6 months was 5.6 (3.4– 7.1) hours/night with 73.3% of subjects using CPAP ≥4 h/night. No association was found between compliance and different socio-economic classes for people in work, type D personality, education level, sex, age, baseline ESS or ODI. The clinician’s initial impression could separate groups of good and poor compliers but had little predictive value for individual patients. Compared to subjects who were working, those who were long term unemployed had a lower CPAP usage and were more likely to use CPAP < 4 h a night (OR 4.6; p value 0.011). A high Beck Depression Index and self-reported anxiety also predicted poor compliance.
Conclusions
In our practice there is no significant association between CPAP compliance with socio-economic status, education or personality type. Long term unemployed or depressed individuals may need more intensive support to gain the optimal benefit from CPAP.
Background
Obstructive sleep apnoea syndrome (OSAS) is a common condition, which can lead to low health status [1] through sleepiness, poor concentration and marital discord [2]. It increases the likelihood of accidents including road traffic collisions [3] and is probably an independent risk factor for cardiovascular mortality and morbidity [4, 5]. Continuous positive airway pressure (CPAP) treatment can reverse daytime sleepiness and in case controlled series is associated with a fall in the number of car crashes and the incidence of strokes and heart attacks [6–8]. The benefit on a number of symptom measures is proportional to the amount of time spent using CPAP [9]. In some series that reported a reduction in cardiovascular disease with CPAP the comparator group with worse outcomes comprised non-acceptors of CPAP [10]. Compliance with CPAP is therefore key to its effectiveness. Initial acceptance of treatment has been reported to be as good as 84% [11] but historical series have reported that as few as 46% of initial acceptors subsequently used CPAP for more than 4 h/night [12]. In more recent studies of interventions to improve compliance the use of CPAP has been found to range between 2 to 8 h [13]. Given the large number of patients treated with CPAP a significant number of symptomatic OSA patients are still left with suboptimal usage.
The initial pattern of compliance is one of the better predictors of long-term use [14]. Interventions that are directed at increasing compliance may be costly [15]. For both of these reasons, it would be most helpful if clinicians could identify the patients who are likely to fail to comply well with treatment before it is initiated, to focus interventions at the start of treatment in those most likely to need extra support. There have been studies investigating associations with poor compliance. Several have reported the impact of nasal and pressure related side effects, but these only become apparent after a period of treatment. The severity of OSA has been shown to have predictive value in some [16] but not all studies [17]. Recent reports have shown associations for both low socio-economic group [18–21] and type D personality (the tendency to suppress emotional distress) [22] with poor compliance though the latter was retrospective. The physician’s ability to predict which patients will be good and poor compliers with CPAP has not been extensively investigated. More recent published work supported adopting a common sense patient centred approach, assessing medical, technical and behavioural factors in improving CPAP compliance [23].
We conducted this prospective study in newly diagnosed OSAS patients to determine which socio-economic and personality factors identified before the initiation of CPAP might be associated with lower rates of initial acceptance and sub-optimal long-term compliance with the therapy.
This study was approved by the Cambridgeshire 1 research and ethics committee (08/H0304/72).
Methods
All individuals referred to a specialist respiratory support and sleep centre and seen initially in our outpatient clinic with suspected OSAS were considered for the study. The diagnosis of OSAS was established on the basis of interview with a sleep specialist and overnight oximetry showing an ODI ≥ 10 per hour. Multi-channel respiratory sleep studies or polysomnography (PSG) were performed if patients with a history strongly suggestive of OSAS had an ODI < 10 per hour or patients had an ODI > 10 per hour and a cardio-respiratory or neurological condition which might produce nocturnal hypoxemia or cause central apnoea or Cheyne - Stokes respiration.
Patients who had a diagnosis of OSAS confirmed and were considered for CPAP treatment were approached to participate in the study. After informed consent subjects completed a range of questionnaires as described below. The following factors were examined looking for their association with CPAP compliance:
Primary factors
-
Socio-economic status – derived by national statistics socio-economic classification (NS-SEC), self coded version [24]. The self-coded version of the national statistics socioeconomic classification was used to assess SEC. This scale takes into account; an individual’s occupational and employment status, size of the employing organisation, self-employed vs. employee, managerial vs. no supervisory role and allocates individuals to one of 6 classes (one class being long term unemployed).
-
Type D personality – also known as distressed personality, reflects an individual’s ability to suppress emotions. This was assessed using a validated tool (DS-14 scale) comprising 7 questions related to negative affectivity or social inhibition [25].
Secondary factors
-
The physician’s estimate of the likelihood that the patient would accept CPAP treatment and subsequently comply with the treatment.
-
Depression – assessed by Beck’s depression inventory 2 (BDI-2). An existing diagnosis of depression was noted. All subjects completed a BDI-2 questionnaire. Those with a score < 13 were classified as normal, 14–19 mild depression, 20–28 moderate depression, and 29–63 severe depression. It is noted that this tool is designed to assess the severity of depression and is not intended as a diagnostic tool
-
Anxiety - self report of previous diagnosis.
-
The patient’s sex
-
Level of education- Educational history was categorised as no formal qualification, school certificate, higher school certificate or bachelor degree.
-
Sleep specific quality of life scores (sleep apnoea quality of life index-SAQLI) score.
-
Epworth sleepiness scale score (ESS)
-
Severity of OSA as assessed by 4% oxygen desaturation index (ODI).
The physician who assessed the patient in clinic estimated the likelihood of the patient accepting the treatment and continuing to use CPAP for > 4 h/night, expressed as a percentage on a visual analogue scale (from 0 to 100). The estimates were based on their impression after reviewing the patient for the first time in clinic and assessing the initial response of patients to the offer of CPAP treatment. The investigators did not ask the clinicians to consider any particular information when evaluating the likelihood of acceptance and compliance with CPAP. The physicians marking the visual analogue scale had from 2 to 25 years of experience in managing sleep disorders.
After consenting to participate in the study, patients were admitted for overnight manual titration with CPAP. Treatment was commenced at a single centre and standard local titration protocols were followed. Next day, patients were discharged on a fixed pressure CPAP device, with the pressure having been determined from the titration night. Choice of mask (nasal vs. full face vs. total face) and humidification usage was influenced by patient choice and comfort, rather than unselective use of either. All the patients had access to the sleep physiologist for a mask or humidification review if needed. This approach potentially reduced the selection bias and was more in keeping with real life clinical management of OSAHS with CPAP.
During subsequent follow-up at 6–10 weeks and 6 months; SAQLI and BDI-2 scores were repeated. Additional questions were asked to assess the individual’s experience of CPAP treatment.
Outcome measures
Individuals who used CPAP and were still using it at second follow-up appointments up to 6 months were designated acceptors. CPAP compliance was measured using an inbuilt counter in the CPAP machine, during the follow-up visits at 6–10 weeks and 6 months. Average CPAP use of less than 4 h/night was considered sub-optimal compliance.
Statistical analysis
Using the socio-economic status variable, it was estimated that 240 patients would give a predictive power to detect a one hour difference in compliance between the different groups. When the results were analysed most of the variables were found to be non-normally distributed and groups were compared using the non-parametric Mann–Whitney U test. To assess the ability of the physician’s confidence that the subject would use CPAP to predict compliance, receiver operator characteristic (ROC) analysis was performed.
Results
The study recruited over a period of 7 months. In this period 566 patients were initiated on CPAP therapy in the sleep centre, 410 of whom were first seen in clinic and were therefore available for the study. Of these, 265 consented to participate in the study. There were 205 men (male to female ratio 3.4:1). Expressed as medians (IQR) the age of participants was 53.0 (44–61) years, ESS 15.0 [11–17], BMI 34.8 (31.6- 41.7) kg/m2, ODI 21.0 (12.3- 41.2) per hour. Type D personality was found in 120 (45%) subjects. At baseline 31.7% were on antidepressants or said that they had previously been diagnosed with depression by their general practitioner and 44.6% of subjects had a BDI-2 score of > 13.
From the cohort of 265 subjects, 9 were switched to a bi-level device, 5 were excluded (one was diagnosed with an upper airway malignancy, another was cured of OSA by tonsillectomy, 3 did not attend any follow-up visit during the study period), 5 withdrew consent. The initial acceptance was calculated as the proportion of individuals still using CPAP after 6 months. Two hundred and twenty one study subjects (89.8%) were still using CPAP at 6 months. There was a strong correlation between the early compliance measured as hours of use at first follow-up, (6–10 weeks) and 6 months compliance with CPAP (r = 0.77) (Fig. 1). The median use at first follow up and 6 months were, 6.0 (4.2-7.5) and 5.6 (3.4- 7.1) hours/night respectively. By our definition of < 4 h/night, 19.0% were using CPAP sub-optimally at first visit and 26.7% at 6 months.
The distribution of different SEC categories within the study population is shown in Table 1. The hours of use in each SEC category at first follow up and at 6 months is shown in Fig. 2a and b respectively. Compared to individuals who were working (or retired from work), those who were long term unemployed had lower median hours of CPAP usage at first follow up and at 6 months (Table 2). This group was also more likely to use CPAP sub-optimally (<4 h/night) at first follow up visit and at 6 months (OR 3.3, and OR 4.6 respectively, see Table 3).
The diagnosing physicians in clinic who recommended the use of CPAP treatment correctly allocated higher and lower likelihoods of compliance to the good and poor complier populations. The group who used CPAP for ≥4 h/night at first visit, were given a likelihood of good compliance of 81%, while those who used CPAP < 4 h/night were given a likelihood of 71%. The difference persisted at 6 months. We looked for a specific cut off point for a physician’s initial impression to predict sub-optimal compliance. Though the sensitivity of predicting suboptimal compliance was 82.5% and specificity 91.1%, when a physician marked ≤ 60% on a visual analogue scale, on ROC analysis area under the curve was only 0.59 (Fig. 3).
At 6 months, the median compliance in individuals with an elevated BDI 2 score (>13) was 5.0 (IQR 2.6 – 7.4) hours/night which was non-significantly lower than the 6.0 (IQR 4.7 – 7.0) hours/night for those whose BDI score was ≤ 13 (Table 2). This difference became more marked for those with BDI score ≥ 29 and was statistically significant (p = 0.028). Current symptoms as measured by a raised BDI predicted poor compliance with CPAP; whereas an existing (and in many cases treated) diagnosis of depression did not. Depression was more common in the subjects who were unemployed and if they were excluded from the analysis there was no longer an association between poor compliance and depression. Self reported anxiety on enrolment to the study also predicted lower hours of use CPAP (Table 2). There was a non-significant trend for individuals with type D personality to comply sub-optimally at 6 months, compared to those who were non-type D. No association was found between hours of use either at first or 6 month follow up and sex, age, baseline ESS, or ODI (Table 2).
Discussion
CPAP treatment for Obstructive sleep apnoea syndrome is rapidly effective with sleepiness and other symptoms best controlled in those who use CPAP for the highest number of hours [6, 8, 9, 26]. It will be best clinical practice and use of resources to identify patients who are likely to have sub-optimal compliance and concentrate interventions to improve usage on those people. In the current study SEC for those in work, level of education and personality type, the severity of sleep apnoea measured by ESS or by ODI, were not good predictors. Our study has shown that the Gestalt impression of the prescribing physician can predict to an extent which patients will be good and less good compliers. Less operator dependent measures, which differentiated these patients at presentation were employment status and a diagnosis of depression.
To date there have been few studies looking at the role of socio-economic status in acceptance and compliance with CPAP treatment in patients with OSAHS. One cross sectional study looking at the pattern of adherence and acceptance of CPAP in an Israeli population found the likelihood of CPAP purchase to be determined by income level [19]. Only 21.8% of individuals with low income accepted and purchased CPAP compared to 51.4% from average and 75.6% from higher income groups. Twenty nine percent of those who declined CPAP cited cost as the reason. In our study no difference in the average compliance or the proportion of people using CPAP sub-optimally, was seen in relation to different socio economic class for those in work. CPAP was provided free of charge at the point of delivery making income level unlikely to be a determinant. There was however significantly lower compliance in individuals who were long term unemployed compared to the ones who were in work with an odds ratio of 4.6 for sub-optimal compliance at 6 months. The number of unemployed individuals was small (19 at the start of the study), and this result may not be generalizable. However, the number of long term unemployed people in the study reflected the unemployment rate in the UK at the time of the study. A study done in a health care system similar to ours found no difference in the compliance between individuals depending on socio-economic background assessed by educational status [27].
Individuals who have high negative affectivity and social inhibition, are classed as Type D personality [25]. Negative emotions in these individuals are likely to be associated with self-neglect with possible implications of poor adherence to treatment. A retrospective study previously described that compliance in those with Type D personality was on an average 1 h 20 min less than those without. Also only 50% of individuals used CPAP ≥4 h/night, compared to 84% of the non-type D personality [22]. Prospectively, in our study individuals with type D personality showed no difference in median compliance compared with non-type D. There was a non-significant trend towards suboptimal compliance with 33% of individuals with type D personality complying sub-optimally compared to 22% with non-type D. It is not clear as to why our results were different than to those of the previous study. A likely explanation is that previous researchers looked at the association retrospectively leading to a recall bias. It is also conceivable that some of the responses to assess social inhibition and negative affectivity may have altered over a period of time, particularly with CPAP intervention that potentially can influence mood and behaviour. This may have led to a smaller proportion of patients with type D in the retrospective study (30% vs 45%) and hence the differences in compliance.
The prevalence of depression as diagnosed by the GP’s, in our population with OSAS offered CPAP, was 32.7% which is higher than estimates for otherwise unselected primary care patients but similar levels found by other investigators (32-48%) in people with OSAS [28, 29]. In our study, current symptoms of depression as measured by a high BDI-2 scores predicted lower compliance at 6 months. Those with a diagnosis of anxiety were less likely to comply optimally at first visit and 6 months. Depression is known to be associated with poor adherence to therapy in other chronic medical disorders [30, 31]. In patients with OSA there is conflicting evidence regarding any association between underlying depression and CPAP use. In a prospective study involving 70 patients, there was no correlation between CPAP compliance at 1 month and underlying depression measured by the Hospital Anxiety and Depression Scale (HADS) scores [32]. In another study using the Minnesota Multiphasic Personality Inventory to measure depression, individuals who were depressed had poor CPAP compliance compared to those who were not depressed [33]. A more recent study found that depression measured on HADS predicted lower Auto CPAP use at one week (R2 = 0.19, p <0.001) [34]. Unemployed individuals, compared to those in work, have a greater chance of poor adherence to chronic medical therapy [35]. They are also more likely to have clinical depression than employed individuals [36]. However, cause and effect association is not clearly established. In our study it is difficult to separate out the effects of depression and unemployment which frequently occurred in the same individuals.
To the best of our knowledge this is the first study to investigate the confidence of a physician in predicting compliance, when they reviewed the patient for the first time. There was an association between a physician’s confidence that the individual would use CPAP and whether they used it 4 or more hours/night. The differences observed were not big; however, they support the hypothesis that a physician can predict CPAP compliance when initiating the treatment. We did not find any association between the physiological variables of severity of OSA, ESS score and CPAP compliance, which has been the experience of other investigators [13, 37, 38].
There are some limitations to the study to consider. The sample size was determined to give adequate power primarily for the SEC status comparisons. There are a number of non-significant trends in the results which might have been found by chance or could have been significant in a larger study. The treatment was free for our subjects but in many health care systems this will not be the case and income levels may be a dominant factor. This affects the generalisability of our results. More than a third of patients seen in clinic did not consent to participation in the study. This may have introduced a selection bias, recruiting individuals with a higher rate of acceptance and compliance but previous audits of our service have shown very similar rates for these parameters [39]. The clinicians involved in scoring the likelihood that subjects would comply with CPAP had a large range of experience. It is possible that if we had focussed just on more experienced staff that the predictive power of the clinician’s impression would have been greater. This might form the basis of a further study.
In this cohort overall initial acceptance of CPAP was 89.8% which compares favourably with published data. However, as in other studies a proportion of patients do not comply well with CPAP. As in other studies early levels of compliance measured as hours of use was highly correlated with long term use (at 6 months). The doctors prescribing CPAP gave patients who complied poorly a higher chance of not complying when asked to predict their usage. People who were long term unemployed and those with a high score on BDI-2 were less likely to use CPAP for ≥4 h/night. Socio-economic status, education level, ESS and ODI did not predict good and poor compliers.
Conclusions
In our practice there is no significant association between CPAP compliance with socio-economic status, education or personality type. Long term unemployed or depressed individuals were less likely to use CPAP optimally and may need more intensive support to gain the optimal benefit from CPAP. Our findings suggest that people who are long term unemployed and/or currently depressed should be identified and offered more intensive support when initiating CPAP therapy to give them the best chance of getting on with the treatment and achieving the benefits that it can offer.
Abbreviations
- AHI:
-
Apnoea Hypopnoea Index
- BDI-2:
-
Beck’s depression inventory 2
- BMI:
-
Body mass index
- CPAP:
-
Continuous positive airway pressure
- HAD:
-
Hospital anxiety and depression scale
- OSA:
-
Obstructive sleep apnoea
- SEC:
-
Socio economic class
References
Stepnowsky C, Johnson S, Dimsdale J, Ancoli-Israel S. Sleep apnea and health-related quality of life in African-American elderly. Ann Behav Med. 2000;22:116–20.
Baron KG, Smith TW, Czajkowski LA, Gunn HE, Jones CR. Relationship quality and CPAP adherence in patients with obstructive sleep apnea. Behav Sleep Med. 2009;7:22–36.
Howard ME, Desai AV, Grunstein RR, Hukins C, Armstrong JG, Joffe D, Swann P, Campbell DA, Pierce RJ. Sleepiness, sleep-disordered breathing, and accident risk factors in commercial vehicle drivers. Am J Respir Crit Care Med. 2004;170:1014–21.
Yaggi HK, Concat J, Kernan WN, Lichtman JH, Brass LN, Mohsenin V. Obstructive sleep apnea as a risk factor for stroke and death. N Engl J Med. 2005;353:2034–41.
Peker Y, Hedner J, Norum J, Kraiczi H, Carlson J. Increased incidence of cardiovascular disease in middle-aged men with obstructive sleep apnea: a 7-year follow-up. Am J Respir Crit Care Med. 2002;166:159–65.
Marin JM, Carrizo SJ, Vicente E, Agusti AG. Long-term cardiovascular outcomes in men with obstructive sleep apnoea-hypopnoea with or without treatment with continuous positive airway pressure: an observational study. Lancet. 2005;365:1046–53.
Cassel W, Ploch C, Becker D, Dugnus D, Peter JH, Von Wichert P. Risk of traffic accidents in patients with Sleep disordered breathing: reduction with nasal CPAP. Eur Respir J. 1996;9:2602–11.
Campos-Rodriguez F, Martinez-Garcia MA, de la Cruz-Moron I, Almeida-Gonzalez C, Catalan-Serra P, Montserrat JM. Cardiovascular mortality in women with obstructive sleep apnea with or without continuous positive airway pressure treatment: a cohort study. Ann Intern Med. 2012;156:115–22.
Weaver TE, Maislin G, Dinges DF, Bloxham T, George CF, Greenberg H, Kader G, Mahowald M, Younger J, Pack A. Relationship between hours of CPAP use and achieving normal levels of sleepiness and daily functioning. Sleep. 2007;30:711–19.
Haentjens P, Van Meerhaeghe A, Moscariello A, De Weerdt S, Poppe K, Dupont A, Velkeniers B. The impact of continuous positive airway pressure on blood pressure in patients with obstructive sleep apnea syndrome: evidence from a meta-analysis of placebo-controlled randomized trials. Arch Intern Med. 2007;167:757–64.
Mark S, Joseph J. The impact of split-night polysomnography for diagnosis and positive pressure therapy titration on treatment acceptance and adherence in sleep apnoea/hypopnea. Sleep. 2000;23:17–24.
Kribbs NB, Pack AI, Kline LR, Smith PL, Schwartz AR, Schubert NM, Redline S, Henry JN, Getsy JE, Dinges DF. Objective measurement of patterns of nasal CPAP use by patients with obstructive sleep apnoea. Am Rev Respir Dis. 1993;147:887–95.
Smith I, Lasserson TJ. Pressure modification for improving usage of continuous positive airway pressure machines in adults with obstructive sleep apnoea. Cochrane Database Syst Rev. 2009.
Budhiraja R, Parthasarathy S, Drake CL, Roth T, Sharief I, Budhiraja P, Saunders V, Hudgel DW. Early CPAP use identifies subsequent adherence to CPAP therapy. Sleep. 2007;30:320–24.
Hoy CJ, Vennelle M, Kingshott RN, Engleman HM, Douglas NJ. Can intensive support improve continuous positive airway pressure use in patients with the sleep apnea/hypopnea syndrome? Am J Respir Crit Care Med. 1999;159:1096–100.
Meurice JC, Dore P, Paquereau J, Neau JP, Ingrand P, Chavagnat JJ, Patte F. Predictive factors of long-term compliance with nasal continuous positive airway pressure treatment in sleep apnea syndrome. Chest. 1994;105:429–33.
Sin DD, Mayers I, Man GC, Pawluk L. Long-term compliance rates to continuous positive airway pressure in obstructive sleep apnea: a population-based study. Chest. 2003;121:430–35.
Billings ME, Auckley D, Benca R, Foldvary-Schaefer N, Iber C, Redline S, Rosen CL, Zee P, Kapur VK. Race and residential socioeconomics as predictors of CPAP adherence. Sleep. 2011;34:1653–58.
Simon-Tuval T, Reuveni H, Greenberg-Dotan S, Oksenberg A, Tal A, Tarasiuk A. Low socioeconomic status is a risk factor for CPAP acceptance among adult OSAS patients requiring treatment. Sleep. 2009;32:545–52.
Bakker JP, O’Keeffe KM, Neill AM, Campbell AJ. Ethnic disparities in CPAP adherence in New Zealand: effects of socioeconomic status, health literacy and self-efficacy. Sleep. 2011;34(11):1595–603.
Campbell A, Neill A, Lory R. Ethnicity and socioeconomic status predict initial continuous positive airway pressure compliance in New Zealand adults with obstructive sleep apnoea. Intern Med J. 2012;42(6):e95–e101.
Broström A, Strömberg A, Mårtensson J, Ulander M, Harder L, Svanborg E. Association of Type D personality to perceived side effects and adherence in CPAP-treated patients with OSAS. J Sleep Res. 2007;16:439–47.
Wickwire EW, Lettieri CJ, Cairns AA, Collop NA. Positive airway pressure adherence in adults. Chest. 2013;144(2):680–93.
Socio-economic classification (United Kingdom) 2001. National Statistics website: http://webarchive.nationalarchives.gov.uk/20160105160709. Accessed 26 Jan 2015.
Denollet J. Type D personality (2000). A potential risk factor defined. J Psychosom Res. 2000;49:255–66.
Filtness AJ, Reyner LA, Horne JA. One night’s CPAP withdrawal in otherwise compliant OSA patients: marked driving impairment but good awareness of increased sleepiness. Sleep Breath. 2012;16:865–71.
Verbraecken J, Lins M, Van Hoof K. CPAP compliance and quality of life (QOL) according to educational level in obstructive sleep apnea (OSA). Eur Respir J. 2005;26 suppl 49:724s.
Aikens JE, Caruana-Montaldo B, Vanable PA, Tadimeti L, Mendelson WB. MMPI correlates of sleep and respiratory disturbance in obstructive sleep apnea. Sleep. 1999;22:362–69.
Akashiba T, Kawahara S, Akahoshi T, Omori C, Saito O, Majima T, Horie T. Relationship between quality of life and mood or depression in patients with severe obstructive sleep apnea syndrome. Chest. 2002;122:861–65.
Smith A, Krishnan JA, Bilderback A, Riekert KA, Rand CS, Bartlett SJ. Depressive symptoms and adherence to asthma therapy after hospital discharge. Chest. 2006;130:1034–38.
Grenard JL, Munjas BA, Adams JL, Suttorp M, Maglione M, McGlynn EA, Gellad WF. Depression and medication adherence in the treatment of chronic diseases in the United States: a meta-analysis. J Gen Intern Med. 2011;26(10):1175–82.
Lewis KE, Seale L, Bartle IE, Watkins AJ, Ebden P. Early predictors of CPAP use for the treatment of obstructive sleep apnea. Sleep. 2004;27:134–38.
Edinger JD, Carwile S, Miller P, Hope V, Mayti C. Psychological status, syndromatic measures, and compliance with nasal CPAP therapy for sleep apnea. Percept Mot Skills. 1994;78:1116–18.
Law M, Naughton M, Ho S, Roebuck T, Dabscheck E. Depression May reduce adherence during CPAP titration trial. J Clin Sleep Med. 2014;10(2):163–9.
Baroletti S, Dell’Orfano H. Medication adherence in cardiovascular disease. Circulation. 2010;121(12):1455–8.
Jefferis BJ, Nazareth I, Marston L, Moreno-Kustner B, Bellón JÁ, Svab I, Rotar D, Geerlings MI, Xavier M, Goncalves-Pereira M, Vicente B. Associations between unemployment and major depressive disorder: evidence from an international, prospective study (the predict cohort). Soc Sci Med. 2011;73(11):1627–34.
Krieger J, Kurtz D, Petiau C, Sforza E, Trautmann D. Long-term compliance with CPAP therapy in obstructive sleep apnea patients and in snorers. Sleep. 1996;19:S136–43.
McArdle N, Devereux G, Heidarnejad H, Engleman HM, Mackay TW, Douglas NJ. Long-term use of CPAP therapy for sleep apnea/hypopnea syndrome. Am J Respir Crit Care Med. 1999;159:1108–14.
Gulati A, Morrish E, Pilsworth S, Quinnel T, Shneerson JM, Smith IE. Long term compliance on CPAP, Papworth experience. J Sleep Res. 2008;17 Suppl 1:45.
Acknowledgement
We would like to thank Dr J Shneersen and Dr P Lawson for their help towards acquisition of data for the study patients.
Funding
There was no funding for this study.
Availability of data and materials
The data that support the findings of this study are available from the corresponding author upon reasonable request.
Authors’ contributions
AG Contribution to concept and design, acquisition of data, analysis, drafting of manuscript. MA Contribution to concept, design of the study and acquisition of data. MD Contribution towards concept, design of the study and acquisition of data. TQ Contribution towards acquisition of data and initial concept/design. IES Contribution towards initial concept and design as well as acquisition of data and drafting of manuscript. All authors read and approved the final manuscript.
Competing interests
All authors certify that they have no affiliations with or involvement in any organization or entity with any financial interest (such as honoraria; educational grants; participation in speakers’ bureaus; membership, employment, consultancies, stock ownership, or other equity interest; and expert testimony or patent-licensing arrangements), or non-financial interest (such as personal or professional relationships, affiliations, knowledge or beliefs) in the subject matter or materials discussed in this manuscript.
Consent for publication
Not applicable.
Ethics approval and consent to participate
All patients signed the informed consent of the study, that was approved by Cambridgeshire 1 research and ethics committee (08/H0304/72).
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Gulati, A., Ali, M., Davies, M. et al. A prospective observational study to evaluate the effect of social and personality factors on continuous positive airway pressure (CPAP) compliance in obstructive sleep apnoea syndrome. BMC Pulm Med 17, 56 (2017). https://doi.org/10.1186/s12890-017-0393-7
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s12890-017-0393-7