Efficacy and safety of long-term use of a positive expiratory pressure device in chronic obstructive pulmonary disease patients, a randomized controlled trial

Abstract

Background

Exercise intolerance is among the most common symptoms experienced by patients with chronic obstructive pulmonary disease (COPD), which is associated with lung dynamic hyperinflation (DH). There was evidence that positive expiratory pressure (PEP), which could be offered by less costly devices, could reduce DH. The purpose of this study was to evaluate the efficacy and safety of long-term domiciliary use of PEP device in subjects with COPD.

Methods

A randomized controlled trial was conducted and 25 Pre-COPD or mild-to-very severe subjects with COPD were randomized to intervention group (PEP device, PEP = 5 cmH2O, n = 13) and control group (Sham-PEP device, PEP = 0 cmH2O, n = 12). PEP device was a spring-loaded resistor face mask. Subjects were treated 4 h per day for a total of 2 months. Six-minute walk test (6MWT), pulmonary function, the Modified British Medical Research Council score, and partial pressure of end-tidal carbon dioxide were evaluated at baseline and after two months.

Results

The 6MWD (− 71.67 ± 8.70 m, P < 0.001), end-dyspnea (P = 0.002), and end-fatigue (P = 0.022) improved significantly in the intervention group when compared with the control group. All subjects in the intervention group reported that 4 h of daily use of the PEP device was well tolerated and accepted and there were no adverse events.

Conclusion

Regular daily use of PEP device is safe and may improve exercise capacity in subjects with COPD or pre-COPD. PEP device could be used as an add-on to pulmonary rehabilitation programs due to its efficacy, safety, and low cost.

Trial registration: The study was prospectively registered on ClinicalTrials.gov (NCT04742114).

Peer Review reports

Background

Chronic obstructive pulmonary disease (COPD) is characterized by persistent and not fully reversible airflow limitation, with high economic and social burden, high morbidity and mortality worldwide [1,2,3,4]. Recently, Pre-COPD highlighted by the Global Initiative for Chronic Obstructive Lung Disease (GOLD) strategy indicated that there are patients with normal lung function, but with structural abnormalities such as emphysema [2]. Emphysema is characterized by air trapping and dynamic hyperinflation (DH) during exercise [5]. DH is implicated as a major cause of dyspnea during physical activity in COPD, which might cause limited exercise capacity [6, 7]. Exercise is a cornerstone of pulmonary rehabilitation for patients with COPD [8], however, the presence of DH during exercise makes it difficult for patients to tolerate higher training intensities [9].

Therefore, reversing DH is important for patients with COPD or Pre-COPD to reduce dyspnea and improve exercise capacity [10]. Pursed lip breathing (PLB) could theoretically provide positive expiratory pressure (PEP), reduce dynamic compression during expiration, attenuate expiratory airflow restriction, and reduce inspiratory threshold load in hyperinflated lungs in patients with COPD [11]. Thus, PLB has been recommended to reduce dyspnea [12]. However, the increase in airway pressure is due to the increased mouth expiratory resistance, which varies with the rate of airflow, is unstable and cannot be quantified [13]. Therefore, the evidence that PLB is beneficial for dyspnea, exercise endurance, and dynamic hyperinflation remains uncertain. Non-invasive ventilation (NIV) has been used as an aid to improve exercise tolerance in patients with COPD [14]. Among NIV modalities, PEP performs the major role in reversing DH, which can be offered by less costly and elementary devices. The PEP, which is believed to have similarities with PLB, could increase intraluminal airway pressure, counteract intrinsic positive end-expiratory pressure (PEEPi) and reduce airway collapse during expiration by moving the airway equal pressure point from the peripheral airway, which is prone to collapse, to a more solid airway in the center. Thus, PEP could reduce airway collapse and DH, and thus possibly reduce dyspnea and improve exercise capacity [15].

PEP devices have been wildly used to produce a reduction of breathing frequency and expiratory flow limitation, change breathing pattern, improve gas exchange, as well as result in less airway collapse and air-trapping in patients with COPD [16,17,18,19,20,21]. Russo D et al. had subjects breathe using different levels of PEP (1 cmH2O and 10 cmH2O) during 6MWT and found that PEP could improve exercise tolerance [18]. Nicolini A et al. had subjects breathe using a simple device with 5 cmH2O PEP in 6MWT and found that PEP significantly improved exercise capacity (walking distance), oxygen saturation and heart rate [16]. Cardoso et al. had subjects breathe with PEP device for 20 min and showed that patients had a better physiological breathing pattern with PEP, which was effective in reducing assisted inspiratory muscle activity and improving ventilation and dyspnea [17]. Therefore, previous studies basically used PEP for breathing only during exercise, a brief process.

However, to our knowledge, few studies to date have explored the effects of long-term domiciliary use of PEP devices on exercise capacity in patients with COPD or Pre-COPD. Therefore, this study aimed to evaluate the effects and safety of long-term domiciliary use of PEP delivered by a spring-loaded resistor face mask in patients with COPD or Pre-COPD.

Methods

Study subjects

Subjects were consecutive screened from the Pulmonary Clinic of a tertiary care teaching hospital from July 2021 to May 2022. Inclusion criteria: (I) Age range: 18 to 80 years; (II) emphysema on CT scan (HU ≥ − 900); (III) no other imaging changes of lung disease such as occupancy, exudation and interstitial changes on CT scan; (IV) no history of lung cancer, lung resection, cystic fibrosis; (V) signed informed consent. Exclusion criteria: (I) with underlying lung disease such as asthma, bronchiectasis and interstitial lung disease; (II) with heart failure; (III) unwilling to participate. All participants were clinically stable at the time of recruitment. All subjects have not recently, or were currently, participating in pulmonary rehabilitation during the time of the study. Informed consent was obtained from all subjects.

Study procedures

All enrolled subjects were randomized into intervention group (with PEP device) or control group (with sham-PEP device) by a sequence of computer-generated randomized numbers. An independent third-party researcher was responsible for generating the allocation sequence (i.e., computer-generated random numbers), and the outcome assessors were unaware of patients’ allocation.

The PEP device was a silicone face mask (PEP device, Xiamen Kangbo Medical facility Company) loaded with a spring linear pressure resistor in a unidirectional expiratory valve and was placed on the subject’s face and held in place with a 4-point strap around the head. The spring linear pressure resistor can be adjustable to provide flow-independent PEP between 5 and 20 cmH2O (Fig. 1). During the inspiratory period, the tiny valve opened to lower the inspiratory pressure. In this trial, the resistor was adjusted to perform a load around 5 cmH2O and was kept the same for the duration of the study, based on previous studies that used these values and encountered some clinical benefits in patients with COPD during exercise[15, 16]. All subjects needed to do was to put on the mask, inhale through the nose and exhale through the nose. But the subjects needed to make sure that the mask was airtight and did not leak. The sham PEP device was not loaded with a spring linear pressure resistor; thus it did not provide PEP. Subjects were advised to use the PEP device at any time of the day, either continuously or intermittently. Subjects were required to ensure a total of 4 h of use per day for a total of two months and were advised to use the device while sitting or walking slowly, and not during strenuous activities such as running.

Fig. 1
figure 1

A showed a subject in the intervention group using PEP device (PEP = 5cmH2O). B showed a spring linear pressure resistor. The sham PEP device used in the control group was not loaded with a spring linear pressure resistor

During the first visit (T0), the self-administered questionnaire was used to record the demographic and clinical characteristics, including age, weight, gender, medical history, tobacco history, pulmonary function tests, COPD grade, drug treatment, 6-min walk test (6MWT), The partial pressure of end-tidal carbon dioxide (PETCO2), and Modified British Medical Research Council score (mMRC score). The breathlessness in daily life was measured by a mMRC score [2]. The PETCO2 was measured by portable PETCO2 capnography monitor (Kingst®, KMI800). All subjects sat for 10 min to reach a steady state before measuring PETCO2, and then were measured PETCO2 in a seated position. The pulmonary function was performed (Master Screen Body, Jager, Germany) according to American Thoracic Society/European Respiratory Society (ATS/ERS) guidelines and measured the forced vital capacity (FVC), the forced expiratory volume in one second (FEV1), FEV1/FVC, inspiratory capacity (IC) and maximum voluntary ventilation (MVV) [22]. The 6MWT was performed in a 30-m long, flat, straight, indoor corridor supervised by a well-trained researcher according to the ATS/ERS guidelines [23]. Instructions were provided prior to the 6MWT and all 6MWTs were conducted by the same investigator. The 6-min walk distance (6MWD) was recorded. Heart rate (HR), oxygen saturation (SPO2) before and after the 6MWT (Initial SPO2 and End SPO2) and the minimal SPO2 during the 6MWT were measured continually through a wrist-worn pulse oximeter (WristOx2, Nonin Medical, Plymouth, MN). Subjects were shown the modified Borg scale before and after the 6MWT to rate their dyspnea and fatigue from 0 to 10, with higher scores indicating worse dyspnea and fatigue. All subjects performed two 6MWTs following the standard procedure mentioned in the guidelines with at least one hour between them and recording the highest 6MWD. After 2 months (T1), during the second visit, the same outcomes were collected and the comfort sensation of using PEP device by a Likert scale from 0 to 10 (0: no discomfort, 10 maximum discomfort) were also collected. For analysis, the ratings were divided into 3 categories: 0 to 3 = ‘not or slightly uncomfortable’, 4 to 6 = ‘moderately uncomfortable’ and 7 to 10 = 'uncomfortable or very uncomfortable’[24]. Primary efficacy outcomes were 6MWD, Borg-Dyspnea and Borg-Fatigue. Primary safety outcomes were PETCO2, PEP device-related discomfort and all adverse events. Adverse events associated with the use of the EPAP device were defined as asphyxia, pressure ulcers, acute deterioration, and death. Secondary outcomes were pulmonary function and mMRC score.

Subjects were contacted by phone every 3 days to confirm their adherence to the device. The subjects were asked about their feelings on using the EPAP device and whether they were still using it every day. All subjects were asked this: “Does anything about using this equipment make you uncomfortable?”, “Do you regularly use this device for 4 h every day?”, and “Do you encounter any issues while using this device?” All subjects received optimal medical therapy as usual according to GOLD guidelines at the time of enrollment. Changes to medication were not permitted throughout the study, unless required for safety [2]. If in doubt, subjects were instructed to consult the investigator any time in addition to scheduled phone interviews. All enrolled subjects were explained that two different forms of devices would be compared, but no further details were disclosed, thus, all enrolled subjects were blind on group allocation. All data analyses were performed with the evaluator blinded to the subjects’ condition.

Statistical analysis

SPSS version 22.0 (SPSS Inc., Chicago, IL, USA) was used for data processing and analysis. Data are presented as mean and standard deviation (mean ± SD), median and interquartile [M(P25, P75)] or frequency counts and percentages. The baseline characteristics were compared using independent samples t-test, Mann–Whitney U test or chi-square test. Paired t-test or Wilcoxon test was used for before-and-after comparisons within the intervention or control groups. Independent sample t test was performed for comparisons between groups. P < 0.05 was statistically significant. Subjects were a sample of convenience and the power for this study was 0.82.

Results

Twenty-five consecutive eligible subjects were randomly assigned to either the intervention group (n = 13) or the control group (n = 12), without dropouts and relevant adverse events occurring during the study (Fig. 2). There were no significant differences between two groups at baseline (P > 0.05) (Table 1) and no medication changes for all subjects during the whole procedure. Of all subjects who met the inclusion criteria, all current smokers were advised to quit smoking. Until the end of the trial, all subjects were compliant with the training regime.

Fig. 2
figure 2

Flow of recruitment of study subjects. A total of 25 subjects were eligible for inclusion and underwent randomization in the study, with 12 subjects in the control group (sham- PEP device) and 13 subjects in the intervention group (PEP device)

Table 1 Baseline characteristics

Compared with the control group, 6MWD (− 71.67 ± 8.70 m (95% CI [− 89.67, − 53.67]), P < 0.001), end-dyspnea (P = 0.002) and end-fatigue (P = 0.022) were significantly improved in the intervention group and PETCO2 was significantly lower in the intervention group (2.33 ± 0.43 mmHg, (95% CI [1.53, 3.12]), P < 0.001). All subjects adopted the PEP device stated that using PEP device in daily life was well acceptable. (Likert scale 1(0.5,1.25)) and there were no complications or adverse events. More details were shown in Table 2 and Fig. 3.

Table 2 Primary efficacy and safety outcomes
Fig. 3
figure 3

Primary efficacy and safety outcomes. A Showed the 6MWD at baseline (T0) and two months later (T1) in the intervention group (solid circles) or control group (solid squares). B Showed the Borg-dyspnea score at the end of the 6MWT at baseline (T0) and two months later (T1) in the intervention group (solid circles) or control group (solid squares). C Showed the Borg-fatigue score at the end of the 6MWT at baseline (T0) and two months later (T1) in the intervention group (solid circles) or control group (solid squares). D Showed the PETCO2 at baseline (T0) and two months later (T1) in the intervention group (solid circles) or control group (solid squares). T0 refers to the time when subjects were enrolled. T1 refers to the time when subjects were followed up at 2 months after enrollment. (*: P < 0.05; **: P < 0.001)

Compared with the control group, the initial SpO2 (1.13 ± 0.39% (95% CI [0.34, 1.93]), P = 0.007), minimal SpO2 (1.45 ± 0.36% (95% CI [0.70, 2.20]), P = 0.001), FEV1/ FVC (7.00 ± 2.85% (95% CI [1.10, 12.90]), P = 0.022) and mMRC (P = 0.003) was higher in the intervention group. More details were shown in Table 3 and Fig. 4.

Table 3 Secondary outcomes
Fig. 4
figure 4

Secondary outcomes. A Showed the SpO2 at the beginning of the 6MWT at baseline (T0) and two months later (T1) in the intervention group (solid circles) or control group (solid squares). B Showed the minimal SpO2 during the 6MWT at baseline (T0) and two months later (T1) in the intervention group (solid circles) or control group (solid squares). C Showed the SpO2 at the end of the 6MWT at baseline (T0) and two months later (T1) in the intervention group (solid circles) or control group (solid squares). D Showed the FEV1/FVC at baseline (T0) and two months later (T1) in the intervention group (solid circles) or control group (solid squares). E Showed the MVV at baseline (T0) and two months later (T1) in the intervention group (solid circles) or control group (solid squares). F Showed the mMRC score at baseline (T0) and two months later (T1) in the intervention group (solid circles) or control group (solid squares). T0 refers to the time when subjects were enrolled. T1 refers to the time when subjects were followed up at 2 months after enrollment. (*: P < 0.05; **: P < 0.001)

Discussion

To the best of our knowledge, this is the first randomized controlled trial to evaluate the effects of using PEP device during activities of daily living on exercise capacity in patients with COPD or Pre-COPD. The major findings of the present study are as follows: (1) Patients in the intervention group showed significant improvement in exercise tolerance after one month of using the PEP device (5 cmH2O), as evidenced by improved walking distance, significant improvement in dyspnea and fatigue after 6MWT and significant improvement in minimal SPO2 during 6MWT (all P < 0.05). Meanwhile, the use of the PEP device resulted in a mean 6MWD change of 71.67 ± 8.70 m and a mean Borg scale change in dyspnea at the end of the exercise of 1 (0.5–1.75) units, which were above the established minimal clinically important difference (MCID) [25, 26]; (2) Patients in the intervention group showed significant improvement in FEV1/FVC (P < 0.05); (3) There was a significant and clinically relevant decrease in activity-related dyspnea in the intervention group (P < 0.05), measured with the mMRC scale.

Dyspnea is a common symptom reported by patients with COPD, despite optimal medical management, the use of supplemental oxygen and PLB [27]. PEP could increase bronchial pressure, which can counteract intrinsic positive end-expiratory pressure and move the equal pressure point back to more central and solid airways, alleviate early dynamic airway compression on expiration and attenuate expiratory airflow limitation, which may result in more homogenous ventilation and improved gas exchange [15, 21, 27]. PEP could reduce the inspiratory threshold load of hyperinflated lungs in COPD during exercise, promoting an enhancement in neuromuscular coupling [28]. PEP could change breathing patterns and prolong expiratory time, and thereby reduce lung volumes and DH [19]. PEP devices we used were lower-cost, which facilitated their use in daily life for patients.

Monteiro et al. indicated that a small improvement in DH observed with PEP might lead to greater exercise endurance and reduced dyspnea [21]. However, they suggested that PEP devices increased expiratory effort, which may increase dyspnea and counterbalance the benefits of DH improvement [21]. We observed an improvement in mMRC score and a significant reduction in end-dyspnea after two months of PEP use, and subjects did not experience an increase in dyspnea. It is possible that PEP devices in our study were used during daily life rather than during strenuous exercise on a treadmill as in Monteiro et al. [21]. Another study conducted by Wibmer et al. noted that nasal PEP device reduced DH during 6MWT, but without an improvement in walking distance, possibly because the reduction of DH resulting from short application of the PEP device may not result in an acute improvement in exercise endurance, as subjects might require time to derive an advantage from their improved ventilatory capacity resulting from the reduction in DH [29]. The subjects in our study used the PEP device for 4 h per day for two months to improve DH, and 6MWD was significantly improved. Moreover, the PEP device used by Wibmer et al. provided the PEP of 10 cmH2O, and it has been shown that lower level of PEP may be more beneficial [18, 29]. The PEP used in our study was 5 cmH2O, which was similar with the pressure produced by PLB [15]. PEP of 5 cmH2O improved the exercise tolerance and did not cause significant discomfort such as dyspnea. Vanderschans GP et al. conducted a randomized cross-over controlled trial of eight male patients, all of whom performed two incremental cycling exercises while breathing with or without a PEP device, respectively [15]. They found that PEP may increase dyspnea, which may be related to the high intensity of exercise in their study. The high intensity exercise would make subjects more likely to exertional breathing and make PEP effects underestimated. In another study, subjects in the intervention group was breathing through a flow-dependent PEP device, which may produce a positive pressure of 4–20 cmH2O during leg extension exercise. The results showed that the subjects had improved DH, but did not reach statistical significance [20]. They noted that such leg exercising may involve an element of anaerobic metabolism and consequently they may have underestimated the benefit of PEP during purely aerobic exercise such as walking.

Nicolini et al. indicated that PEP (5 cmH2O) improved 6MWD and post-exercise SpO2, which was similar to our findings, and we also found a significant improvement in minimal SpO2 during 6MWT [16]. The PEP device could prevent the airway collapse, which results in more homogeneous ventilation. Thus, improved ventilation-perfusion distribution probably results in reduced dead space waste, improved alveolar ventilation, and improved SpO2 [20]. In our study, we observed an improvement in initial SpO2, which showed that that gas exchange improved after two months. Exercise intolerance in COPD is also associated with reduced IC and occurs with a neuromuscular “power reserve”, which is associated with resting FEV1/FVC [30]. IC, which represents the true operating limits for tidal volume expansion in patients with expiratory flow limitation during exercise, is an important surrogate measurement for COPD [31]. The FEV1/FVC, one of the spirometry measurements, was associated with expiratory flow limitation and used to classify the airflow limitation severity of patients with COPD [2]. We found there was a significant improvement in FEV1/FVC for subjects with EPAP device after 2 months and an improvement in IC without reaching statistical significance in our study, which may be due to IC at baseline having a higher value. Resting IC as a percentage of the predicted value was above 80% for all subjects in our study, which may be due to the fact that the majority of subjects had pre-COPD or mild COPD [7]. Monteiro et al. demonstrated an increase in IC in patients with moderate to severe COPD treated with EPAP at 5 to 10 cmH2O after submaximal treadmill exercise [21].

Regarding the safety of PEP devices, our study showed that daily use of PEP devices did not cause carbon dioxide (CO2) retention, but rather reduced the PETCO2, suggesting that the EPAP device alleviated airway obstruction and improved ventilation. VanderSchans et al.[15] showed that CO2 retention were increased in patients with COPD who breathed through a PEP device at 5 cmH2O during exercise. They hypothesized that insufficient positive pressure was generated to reduce airway closure and that using higher positive expiratory pressure would be more effective during exercise. Padkao et al.[20] applied conical-PEP with 13 cmH2O for patients, and the PETCO2 and SPO2 was not significantly altered, indicating that conical-PEP device with 13 cmH2O allowed appropriate gas exchange. Meanwhile, we observed an improvement in SPO2 in patients with PEP device. These indicated that PEP device used in our study did not have any adverse effects on CO2 retention or SPO2. In addition, the PEP device used in our study proved to be acceptable to the patients when used in daily life. More than 80% of those eligible patients were willing to try it, and of those who were willing, all found it acceptable. When used daily for 4 h a day, there were no adverse effects.

This study has some important limitations. First, the subject sample in our study was small, including subjects with a wide range of disease severity. It can be argued that the heterogeneity of the subjects could have affected the response to the intervention. Therefore, future studies should focus on a larger sample with a more homogeneous population, such as those with consistent disease severity, to avoid underestimating or overestimating the true effect of PEP devices. Second, the recommendation of 4 h of the use of PEP device has no real scientific background. Subjects may accept and tolerate an average of 4 h of PEP device use per day. However, further studies are needed to decide the duration of optimal use. Third, we do not know whether a longer study duration could have resulted in further improvement in lung function, and we expect future studies to clarify these clinically important questions. Fourth, the PEP device used in this study cannot currently be remotely monitored.

Conclusions

In conclusion, regular daily use of PEP device is safe and may improve exercise capacity in patients with COPD or pre-COPD. Meanwhile, the PEP device may be used in the future to assist COPD patients with breathing retraining and symptom management due to its efficiency, safety, simplicity and low cost when compared to other devices and approaches (such as NIV).

Availability of data and materials

Data will be available from the corresponding author on reasonable request.

Abbreviations

COPD:

Chronic obstructive pulmonary disease

DH:

Dynamic hyperinflation

PLB:

Pursed lip breathing

NIV:

Noninvasive ventilation

PEP:

Positive expiratory pressure

mMRC score:

Modified British Medical Research Council score

PETCO2 :

Partial pressure of end-tidal carbon dioxide

6MWT:

6-Minute walk test

GOLD:

Global Initiative for Chronic Obstructive Lung Disease

BMI:

Body Mass Index

ATS/ERS:

American Thoracic Society/European Respiratory Society

FVC:

Forced vital capacity

FEV1 :

Forced expiratory volume in one second

IC:

Inspiratory capacity

MVV:

Maximum voluntary ventilation

6MWD:

6-Minute walking distance

HR:

Heart rate

SPO2 :

Oxygen saturation

CO2 :

Carbon dioxide

References

  1. Maltais F, Decramer M, Casaburi R, Barreiro E, Burelle Y, Debigare R, Dekhuijzen PNR, Franssen F, Gayan-Ramirez G, Gea J, et al. An Official American Thoracic Society/European Respiratory Society statement: update on limb muscle dysfunction in chronic obstructive pulmonary disease executive summary. Am J Respir Crit Care Med. 2014;189(9):1121–37.

    Article  Google Scholar 

  2. Global Strategy for the diagnosis, management and prevention of COPD, Global Initiative for Chronic Obstructive Lung Disease. GOLD 2021.

  3. Wang C, Xu J, Yang L, Xu Y, Zhang X, Bai C, Kang J, Ran P, Shen H, Wen F, et al. Prevalence and risk factors of chronic obstructive pulmonary disease in China (the China Pulmonary Health [CPH] study): a national cross-sectional study. Lancet. 2018;391(10131):1706–17.

    Article  Google Scholar 

  4. Organisation WH. The top 10 causes of death. Available at: https://www.whoint/news-room/fact-sheets/detail/the-top-10-causes-of-death (2020).

  5. Rossi A, Aisanov Z, Avdeev S, Di Maria G, Donner CF, Luis Izquierdo J, Roche N, Similowski T, Watz H, Worth H, et al. Mechanisms, assessment and therapeutic implications of lung hyperinflation in COPD. Respir Med. 2015;109(7):785–802.

    Article  Google Scholar 

  6. Agusti A, Hogg JC. Update on the pathogenesis of chronic obstructive pulmonary disease. N Engl J Med. 2019;381(13):1248–56.

    Article  CAS  Google Scholar 

  7. O’Donnell DE, Elbehairy AF, Webb KA, Neder JA. Canadian Resp Res N: the link between reduced inspiratory capacity and exercise intolerance in chronic obstructive pulmonary disease. Ann Am Thorac Soc. 2017;14:S30–9.

    Article  Google Scholar 

  8. Spruit MA, Singh SJ, Garvey C, ZuWallack R, Nici L, Rochester C, Hill K, Holland AE, Lareau SC, Man WDC, et al. An Official American Thoracic Society/European Respiratory Society Statement: Key Concepts and Advances in Pulmonary Rehabilitation. Am J Respir Crit Care Med. 2013;188(8):E13–64.

    Article  Google Scholar 

  9. Nici L, Donner C, Wouters E, Zuwallack R, Ambrosino N, Bourbeau J, Carone M, Celli B, Engelen M, Fahy B, et al. American thoracic society/European respiratory society statement on pulmonary rehabilitation. Am J Respir Crit Care Med. 2006;173(12):1390–413.

    Article  Google Scholar 

  10. O’Donnell DE, Webb KA. The major limitation to exercise performance in COPD is dynamic hyperinflation. J Appl Physiol. 2008;105(2):753–5.

    Article  Google Scholar 

  11. Fregonezi GAD, Resqueti VR, Rous RG. Pursed lips breathing. Arch Bronconeumol. 2004;40(6):279–82.

    Article  Google Scholar 

  12. Pereira de Araujo CL. Karloh M, dos Reis CM, Palu M, Mayer AF. Pursed-lips breathing reduces dynamic hyperinflation induced by activities of daily living test in patients with chronic obstructive pulmonary disease: a randomized crossover study. J Rehabil Med. 2015;47(10):957–62.

    Article  Google Scholar 

  13. Spahija J, de Marchie M, Grassino A. Effects of imposed pursed-lips breathing on respiratory mechanics and dyspnea at rest and during exercise in COPD. Chest. 2005;128(2):640–50.

    Article  Google Scholar 

  14. Dennis CJ, Menadue C, Schneeberger T, Leitl D, Schoenheit-Kenn U, Hoyos CM, Harmer AR, Barnes DJ, Koczulla AR, Kenn K, et al. Bilevel noninvasive ventilation during exercise reduces dynamic hyperinflation and improves cycle endurance time in severe to very severe COPD. Chest. 2021;160(6):2066–79.

    Article  Google Scholar 

  15. Vanderschans GP, Dejong W, Devries G, Kaan WA, Postma DS, Koeter GH, Vandermark TW. Effects of positive expiratory pressure breathing during exercise in patients with COPD. Chest. 1994;105(3):782–9.

    Article  CAS  Google Scholar 

  16. Nicolini A, Merliak F, Barlascini C. Use of positive expiratory pressure during six minute walk test: results in patients with moderate to severe chronic obstructive pulmonary disease. Multidiscip Respirat Med. 2013, 8.

  17. Cardoso DM, Fregonezi GAF, Jost RT, Gass R, Alberton CL, Albuquerque IM, Paiva DN, Barreto SSM. Acute effects of Expiratory Positive Airway Pressure (EPAP) on different levels in ventilation and electrical activity of sternocleidomastoid and parasternal muscles in Chronic Obstructive Pulmonary Disease (COPD) patients: a randomized controlled trial. Braz J Phys Ther. 2016;20(6):525–34.

    Article  Google Scholar 

  18. Russo D, Simonelli C, Paneroni M, Saleri M, Piroddi IMG, Cardinale F, Vitacca M, Nicolini A. Is there an optimal level of positive expiratory pressure (PEP) to improve walking tolerance in patients with severe COPD? Arch Bronconeumol. 2016;52(7):354–60.

    Article  Google Scholar 

  19. Gass R, Merola P, Monteiro MB, Cardoso DM, Paiva DN, Teixeira PJZ, Knorst MM, Berton DC. Effects of expiratory positive airway pressure on exercise tolerance, dynamic hyperinflation, and dyspnea in COPD. Respir Care. 2017;62(10):1298–306.

    Article  Google Scholar 

  20. Padkao T, Boonsawat W, Jones CU. Conical-PEP is safe, reduces lung hyperinflation and contributes to improved exercise endurance in patients with COPD: a randomised cross-over trial. J Physiother. 2010;56(1):33–9.

    Article  Google Scholar 

  21. Monteiro MB, Berton DC, Fontoura Moreira MA, Menna-Barreto SS, Zimermann Teixeira PJ. Effects of expiratory positive airway pressure on dynamic hyperinflation during exercise in patients with COPD. Respir Care. 2012;57(9):1405–12.

    Article  Google Scholar 

  22. Miller MR, Hankinson J, Brusasco V, Burgos F, Casaburi R, Coates A, Crapo R, Enright P, van der Grinten CPM, Gustafsson P, et al. Standardisation of spirometry. Eur Respir J. 2005;26(2):319–38.

    Article  CAS  Google Scholar 

  23. Crapo RO, Casaburi R, Coates AL, Enright PL, MacIntyre NR, McKay RT, Johnson D, Wanger JS, Zeballos RJ, Bittner V, et al. ATS statement: guidelines for the six-minute walk test. Am J Respir Crit Care Med. 2002;166(1):111–7.

    Article  Google Scholar 

  24. Dawes J. Do data characteristics change according to the number of scale points used? An experiment using 5-point, 7-point and 10-point scales. Int J Mark Res. 2008;50(1):61–77.

    Article  Google Scholar 

  25. Holland AE, Spruit MA, Troosters T, Puhan MA, Pepin V, Saey D, McCormack MC, Carlin BW, Sciurba FC, Pitta F, et al. An official European Respiratory Society/American Thoracic Society technical standard: field walking tests in chronic respiratory disease. Eur Respir J. 2014;44(6):1428–46.

    Article  Google Scholar 

  26. Ries AL. Minimally clinically important difference for the UCSD Shortness of Breath Questionnaire, Borg Scale, and Visual Analog Scale. COPD. 2005;2(1):105–10.

    Article  Google Scholar 

  27. Martin AD, Davenport PW. Extrinsic threshold PEEP reduces post-exercise dyspnea in COPD patients: a placebo-controlled, double-blind cross-over study. Cardiopulm Phys Therapy J. 2011;22(3):5–10.

    Article  Google Scholar 

  28. Ambrosino N, Strambi S. New strategies to improve exercise tolerance in chronic obstructive pulmonary disease. Eur Respir J. 2004;24(2):313–22.

    Article  CAS  Google Scholar 

  29. Wibmer T, Ruediger S, Heitner C, Kropf-Sanchen C, Blanta I, Stoiber KM, Rottbauer W, Schumann C. Effects of nasal positive expiratory pressure on dynamic hyperinflation and 6-minute walk test in patients with COPD. Respir Care. 2014;59(5):699–708.

    Article  Google Scholar 

  30. Cao M, Calmelat RA, Kierstead P, Carraro N, Stringer WW, Porszasz J, Casaburi R, Rossiter HB. A randomized, crossover, placebo controlled, double-blind trial of the effects of tiotropium-olodaterol on neuromuscular performance during exercise in COPD. J Appl Physiol. 2022;132(5):1145–53.

    Article  CAS  Google Scholar 

  31. O’Donnell DE, Guenette JA, Maltais F, Webb KA. Decline of resting inspiratory capacity in COPD the impact on breathing pattern, dyspnea, and ventilatory capacity during exercise. Chest. 2012;141(3):753–62.

    Article  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

This work was supported by Qilu Hospital Of Shandong University [Grant Number: 2018–6].

Author information

Authors and Affiliations

Authors

Contributions

Conceptualization: [ZN Xu]; Methodology: [ZN Xu]; Formal analysis and investigation: [ZN Xu, DD Ma, Z Han]; Data collection: [ZN Xu, DD Ma]; Writing—original draft preparation: [ZN Xu, DD Ma, Z Han]; Writing—review and editing: [ZN Xu, DD Ma, Z Han]; Funding acquisition: [DD Ma]; Supervision: [DD Ma]. All authors read approved the final manuscript.

Corresponding author

Correspondence to Dedong Ma.

Ethics declarations

Ethics approval and consent to participate

All procedures performed in studies involving human participants were in accordance with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. The trial was approved by Medical Ethics Committee of Qilu Hospital of Shandong University (No. 2020039). Informed consent was obtained from all individual participants included in the study.

Consent for publication

Informed consent was obtained from all individual participants and publication of identifying information/images included in the study.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Xu, Z., Han, Z. & Ma, D. Efficacy and safety of long-term use of a positive expiratory pressure device in chronic obstructive pulmonary disease patients, a randomized controlled trial. BMC Pulm Med 23, 17 (2023). https://doi.org/10.1186/s12890-023-02319-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12890-023-02319-5

Keywords