Comparison of serious inhaler technique errors made by device-naïve patients using three different dry powder inhalers: a randomised, crossover, open-label study

Abstract

Background

Serious inhaler technique errors can impair drug delivery to the lungs. This randomised, crossover, open-label study evaluated the proportion of patients making predefined serious errors with Pulmojet compared with Diskus and Turbohaler dry powder inhalers.

Methods

Patients ≥18 years old with asthma and/or COPD who were current users of an inhaler but naïve to the study devices were assigned to inhaler technique assessment on Pulmojet and either Diskus or Turbohaler in a randomised order. Patients inhaled through empty devices after reading the patient information leaflet. If serious errors potentially affecting dose delivery were recorded, they repeated the inhalations after watching a training video. Inhaler technique was assessed by a trained nurse observer and an electronic inhalation profile recorder.

Results

Baseline patient characteristics were similar between randomisation arms for the Pulmojet-Diskus (n = 277) and Pulmojet-Turbohaler (n = 144) comparisons. Non-inferiority in the proportions of patients recording no nurse-observed serious errors was demonstrated for both Pulmojet versus Diskus, and Pulmojet versus Turbohaler; therefore, superiority was tested. Patients were significantly less likely to make ≥1 nurse-observed serious errors using Pulmojet compared with Diskus (odds ratio, 0.31; 95 % CI, 0.19–0.51) or Pulmojet compared with Turbohaler (0.23; 0.12–0.44) after reading the patient information leaflet with additional video instruction, if required.

Conclusions

These results suggest Pulmojet is easier to learn to use correctly than the Turbohaler or Diskus for current inhaler users switching to a new dry powder inhaler.

Trial registration

ClinicalTrials.gov Identifier: NCT01794390 (February 14, 2013)

Peer Review reports

Background

Serious inhaler technique errors made by patients with asthma and chronic obstructive pulmonary disease (COPD) are common in real life with both pressurised metered dose inhalers (pMDIs) and dry powder inhalers (DPIs) despite advances in inhaler device technology [1, 2]. Although study results vary, estimates of those making inhaler errors range up to 92 % of patients using pMDIs [3] and up to 54 % of patients using DPIs [2].

There is increasing evidence to suggest that correct inhaler technique (mastery) is fundamental for effective therapy [1, 4, 5] and that inhaler device type and mastery play important roles in improving adherence, clinical outcomes, quality of life, and use of healthcare resources [1, 610]. Poor inhaler technique can significantly reduce effective delivery of the respirable fraction of the emitted dose that reaches the lungs [5, 1117]. Evidence suggests that prescribers should consider inhaler technique and ease of use before changing the dose of inhaled corticosteroids, switching to a different inhaler, or adding other treatments to the regimen of patients with poorly controlled asthma [11, 18]. Recent international asthma guidelines highlight the importance of testing and ensuring inhaler technique mastery, alongside checking adherence, before increasing or changing therapy [19].

Correct inhaler technique involves some common steps for all devices (dose preparation, device orientation, full exhalation, deep inhalation, breath hold). However, dose preparation and device orientation differ between devices, highlighting the need for tailored patient training, testing, and education [5, 6, 18, 20]. An important aspect of inhaler mastery is the absence of serious inhaler technique errors, defined as errors that could affect adequate dose delivery to the lungs (also referred to as critical or major errors [21, 22]). Innovative and reliable inhalers that are associated with a reduced risk of serious errors, as compared with current commonly used inhalers, are needed to improve effective use, adherence, and disease control [1, 5, 7, 14, 15, 23].

The Pulmojet®Footnote 1 inhaler, shown in Fig. 1, is a new, prefilled DPI device that has been designed to minimise the likelihood of serious errors by reducing the number of steps required to prepare the dose. It has been designed with a mechanism that releases the dose when a set inhalation flow has been achieved. This ensures efficient de-aggregation of the dose during each inhalation, and the device can be held in any position (even downwards) during dose preparation. This design may facilitate inhaler device training, shortening its required duration and frequency. The aim of this cross-sectional, randomised, open-label study was to explore the proportion of patients making serious errors during their first training session with Pulmojet (not available for prescription during the study) as compared with two other commonly used DPIs.

Fig. 1
figure 1

The Pulmojet inhaler

Methods

Study design and patients

The Handling Inhalers – Technique Error Comparison (HI-TEC) Study was a single-visit, randomised, crossover, open-label study of patients with an established diagnosis of asthma and/or COPD, designed to evaluate serious errors in (a) the use of the patient’s own current inhaler (Turbohaler®,Footnote 2 Diskus®,Footnote 3 or pMDI) and (b) the first time use of a Pulmojet inhaler compared with a Turbohaler or Diskus inhaler for patients naïve to test devices (Fig. 2). The study was conducted between September 2013 and March 2014 at general practices in England and Scotland.

Fig. 2
figure 2

Study design showing phases 1 and 2

The study was performed in compliance with Good Clinical Practice and in accordance with the principles of the Declaration of Helsinki. It was approved by the National Research Ethics Service Cambridge East Research Ethics Committee (13/EE/0073) and by the NIHR Coordinated System for Gaining NHS Permissions (2013GP22 - 116238) (ClinicalTrials.gov Identifier: NCT01794390). In addition, local National Health Service (NHS) research governance approval was obtained from all participating practices.

To be eligible for the study, patients were required to meet the following inclusion criteria: age 18 years or older, current asthma and/or COPD physician diagnosis, current therapy including either inhaled corticosteroid or fixed-dose combination inhaled corticosteroid/long-acting beta-agonist administered through a pMDI, Turbohaler, or Diskus device, and able and willing to read and comprehend written and verbal instructions and to provide written informed consent. In addition, all patients using a Turbohaler or pMDI were required to have no use of the Diskus device in the prior year (Diskus-naïve) and all patients using a Diskus were required to have no use of the Turbohaler device in the prior year (Turbohaler-naïve). No patients had experience of Pulmojet, which remained unavailable for prescription throughout the study.

Key exclusion criteria were receipt of oral corticosteroids and/or antibiotics for a lower respiratory condition in the 4 weeks preceding the study and being considered by the study nurse to be clinically unsuitable for study inclusion for safety reasons (eg, unsafe for the patient to perform multiple inhalations for error assessments and flow measurements).

Eligible patients were identified from primary care practices using routine electronic medical record data. Patients who accepted the mailed invitation to participate in the study were scheduled for a single study visit at which their eligibility was confirmed, written informed consent was recorded, and their inhaler technique was assessed, as described below.

Phase 1

An electronic case report form was used to record patient demographic information and the routine clinical assessment, including the number of exacerbations in the previous 12 months, drawing on information in the patient’s medical record as necessary.

Patients were told to withhold their morning medication and to bring their current inhaler devices to the clinic. They underwent assessment of their current inhaler technique, first using their active inhaler device and assessed by trained nurse observers (using a predefined error check-list). Second, patients were then asked to repeat their inhalation manoeuvre using an empty version of their current device (containing no drug or placebo formulation), and their inhaler inhalation was assessed by an electronic inhalation profile recorder (technology assessment, described below).

Phase 2

Patients were allocated into the study comparison according to their current device (see Fig. 2): current pMDI and Turbohaler users were allocated to the Pulmojet-Diskus comparison and current Diskus users were allocated to the Pulmojet-Turbohaler comparison. The pMDI users were included in the Pulmojet-Diskus comparison to attain the greater numbers required according to the power calculations (see below).

The study was conducted by primary care respiratory research nurses who had prior experience and received instruction in inhaler device assessment for the study. To ensure that patient training on the different devices (Pulmojet, the investigative device, and Turbohaler or Diskus, the control devices) was consistent and representative of best standard care, two forms of patient training were utilised: provision of the device’s patient information leaflet and, for those making one or more errors post-leaflet, an instructional video. The training video was designed to be representative of a standardised form of optimal training by a qualified nurse. It was reviewed and approved by the full study steering committee.

After randomisation to device order, the first allocated device and accompanying patient information leaflet were provided to patients; they were given up to 5 min to read the leaflet after which they were evaluated for device handling technique, first by the research nurse, as evaluated against a predefined list of errors, and then via pneumotrac spirometer (details are below). If the research nurse observed no serious errors, testing on the first device was considered to have been completed and the patient was given the second allocated device. If one or more serious errors were observed in the patient’s handling of the first allocated device, the patient continued to video training and their technique was re-evaluated using both nurse-observed and technology assessments. They then repeated the same process for the second device.

Inhaler technique assessment

Inhaler technique was evaluated by both (a) a nurse observer qualified to identify serious errors in device handling technique (see Additional file 1 for the list of predefined errors) and (b) the measurement of an inhalation profile (technology assessment of the inhalation manoeuvre). Inhalation flow against time measurements were downloaded using the inhaler attached to the inlet of a pneumotrac spirometer (Vitalograph Ltd, Maids Moreton, Buckingham, UK) so that patients were instructed to inhale through the spirometer as though through the inhaler device, as previously described [24].

At the end of the study visit, which lasted 1 h, and only after the study device training was completed, patients who demonstrated errors in current device handling were retrained by the study nurse to use their current device correctly.

All devices were empty and since no active medication was administered, efficacious and safe use were not assessed.

Statistical analysis

Determination of sample size

The objective of the analyses was to demonstrate non-inferiority, and, if met, to evaluate for superiority of the Pulmojet device compared with Diskus and Turbohaler in terms of ability to achieve inhaler mastery after standardised training.

The sample sizes were calculated using nQuery Advisor 7.0 (Statistical Solutions, Ltd., Cork, Ireland) and were optimised to maximise power for the primary comparisons (see Additional file 2 for details). Based on primary care audit data from 336 patients, we estimated a success rate of 78.2 % for the Diskus inhaler and a success rate of 38.8 % for Turbohaler. We further estimated the proportion of discordant pairs in the Diskus-naïve vs. Pulmojet comparison to be 0.282 and the proportion of discordant pairs in the Turbohaler-naïve vs. Pulmojet comparison to be 0.563. To test for non-inferiority, the sample size required for the Diskus-naïve vs. Pulmojet comparison to achieve 90 % power (5 % level of significance, one-sided test) was 226, assuming an expected difference in proportions of 0.00 and allowing a difference in proportions (Pulmojet-Diskus) no lower than −0.10. Thus, it was determined that 113 patients would be randomised to Pulmojet first and a further 113 to Diskus first. For the Turbohaler-naïve vs. Pulmojet comparison, the sample size required to achieve 90 % power (5 % level of significance, one-sided test) was 122, assuming an expected difference in proportions of 0.10 and allowing a difference in proportions (Pulmojet-Turbohaler) no lower than −0.10. Sixty-one patients would, therefore, be randomised to Pulmojet and then Turbohaler and 61 to Turbohaler and then Pulmojet assessments.

The total number of patients required to achieve 90 % power was therefore 348. We anticipated an 8 % dropout rate based on a review of anonymous medical records (data not shown); thus, it was determined that 376 patients would be recruited into the study.

Subsequent to the completion of the study it was determined that the per-protocol power calculation underestimated the number of patients required. This is because the 95 % CIs (two-sided) for the non-inferiority calculation are actually equivalent to a one-sided test with 2.5 % significance. A post-hoc revised power calculation, using the assumptions noted above, and 2.5 % significance level, would have required 276 patients for the Pulmojet-Diskus comparison and 148 patients for the Pulmojet-Turbohaler comparison. As noted below, in fact the numbers of eligible patients included in the analyses were 277 and 144, respectively (421 total), which essentially also met the 95 % CIs (two-sided) for the non-inferiority calculation and one-sided test with 2.5 % significance needs of the post-hoc power calculation.

Baseline data

Baseline data were analysed for all enrolled patients and for the full analysis set, which included all patients who completed an assessment of nurse-observed errors on both study devices. Descriptive statistics were used to summarise patient demographic and baseline clinical characteristics. Current device arms were compared using parametric or non-parametric tests, as appropriate: for variables measured on the interval or ratio scale, an F-test or Kruskal-Wallis test (depending on the distribution of the variable) was used; for categorical variables, a Pearson’s χ2 (or Fisher’s exact test if cell sizes were sufficient) was used. Randomisation orders were compared for patient baseline characteristics using the Mann–Whitney and χ2 test.

Outcome measures

All analyses were carried out using the full analysis set, thus permitting a paired analysis of results.

Primary endpoint

To determine non-inferiority in device handling of the Pulmojet compared with the comparator device (Diskus or Turbohaler), the proportions of patients achieving an absence of serious errors on each device, and the difference in proportions, were analysed using a conditional binary logistic regression model. Non-inferiority in device handling was considered to have been achieved if the proportion of patients recording an absence of nurse-observed serious errors on the Pulmojet was no more than 10 % lower than the proportion of patients recording an absence of nurse-observed serious errors on the comparator device, namely, if the lower bound of the 95 % CI of the difference in proportions of patients recording an absence of serious errors was > −0.10.

Where non-inferiority was demonstrated, superiority was evaluated and claimed if the proportion of patients recording no nurse-observed serious errors on the Pulmojet was significantly greater than the proportion of patients recording no nurse-observed serious errors on the comparator device, namely, if the lower bound of the 95 % CI of the difference in proportions of patients recording no serious errors was >0.00. To provide an additional measure of effect size, a conditional logistic regression was used to compare the odds of recording a serious error. Superiority was also shown if the 95 % CI for the odds ratio of recording an error using Pulmojet compared with the comparator device fell entirely to the left of 1.00. The number of nurse-observed inhaler technique errors was summarised and compared between inhaler types using the Wilcoxon matched pair signed-rank test.

Post-hoc sensitivity analysis

A post-hoc sensitivity analysis restricted to errors that were definitely serious (ie, those that would definitely preclude adequate dose delivery to the lungs) was also conducted.

Secondary endpoint

Technology-assessed inhalation errors (defined as errors recorded by the pneumotrac spirometer) were combined with nurse-observed serious errors (excluding inhalation errors).

Statistically significant results were defined as p < 0.05. All analyses were carried out using SPSS version 22, SAS version 9.3, and Microsoft Office EXCEL 2007.

Results

Patients

Figure 3 shows the disposition of patients recruited into the study. Although the planned recruitment was 376 patients, 430 patients were actually recruited because of simultaneous recruitment across multiple sites. Of 430 recruited patients, 421 (98 %) completed the study and were included in the full analysis set (all patients who completed an assessment of nurse-observed errors on both study devices).

Fig. 3
figure 3

Disposition of study patients

Table 1 presents baseline patient characteristics for the Diskus-naïve vs. Pulmojet-naïve and Turbohaler-naïve vs. Pulmojet-naïve comparisons. Patients first randomised to Turbohaler in the Pulmojet vs. Turbohaler comparison had received significantly more courses of oral corticosteroids in the 12 months before entry into the study than did those first randomised to Pulmojet. There were no other statistically significant differences between treatment cohorts (Table 1).

Table 1 Baseline patient characteristics

Phase 1

Patients were first assessed for inhaler technique using their current device: 92 % of patients using a pMDI, 39 % of those using Diskus, and 76 % of those using the Turbohaler made one or more serious errors (nurse observed and technology assessed, detailed data not shown).

Primary endpoint: nurse-observed serious errors

Pulmojet vs. Diskus

Table 2 shows that more patients made errors with Diskus compared with Pulmojet and non-inferiority was found. Further analysis revealed superiority in that patients naïve to both devices had significantly lower odds of making a nurse-observed serious error (p < 0.001), and overall they made significantly fewer nurse-observed serious errors, when using the Pulmojet device compared with Diskus, having read the leaflet and, if required, watched an instructional video (Fig. 4; Tables 2 and 3).

Table 2 Nurse-observed serious errors for Diskus vs. Pulmojet and Turbohaler vs. Pulmojet comparisons: post-patient information leaflet alone and post-leaflet and instructional video
Fig. 4
figure 4

Odds ratio for ≥1 nurse-observed serious errors with Pulmojet relative to Diskus or Turbohaler DPI. (Post-leaflet + video was the primary endpoint.) *Conditional logistic regression (p < 0.001 for all comparisons)

Table 3 Number of patients making 0, 1, and ≥2 nurse-observed serious errors (post-patient information leaflet alone and post-leaflet and instructional video)

The post-leaflet nurse-observed serious errors categorised into preparation, positioning, inhalation, and general knowledge errors are presented in Fig. 5a (see Additional file 1 for further details). More patients made more general knowledge and inhalation errors with Diskus than with Pulmojet, whereas more patients made preparation errors with Pulmojet than with Diskus. In addition, 26 % of patients made a positioning error with the Diskus. Figure 5b shows that post-leaflet and post-leaflet + video, more patients made inhalation and preparation errors with Diskus compared with Pulmojet; in addition, there were positioning errors with the Diskus. As the Pulmojet device is not subject to positioning error, no positioning errors were identified with Pulmojet. On the other hand, more patients did not know how to determine when the device was empty, which was considered a general knowledge error, with Pulmojet than with Diskus (details in Additional file 1: Tables S1 and S2).

Fig. 5
figure 5

a. Percentage of patients recording Pulmojet and Diskus errors post-leaflet alone. b. Percentage of patients recording Pulmojet and Diskus errors post-leaflet and instructional video

The numbers of patients making 0, 1, and ≥2 serious errors are summarised in Table 3.

Pulmojet vs. Turbohaler

Table 2 and Fig. 4 show non-inferiority and also superiority in that fewer patients made nurse-observed serious errors with Pulmojet compared with Turbohaler after the leaflet and video instruction, as well as the leaflet alone. Many patients made more than one error, particularly post-leaflet alone (Table 3).

Serious errors by type are shown in Fig. 6a and b. In addition to making positioning errors with Turbohaler, more patients made general knowledge, inhalation, and preparation errors with Turbohaler than with Pulmojet (Additional file 1: Tables S3 and S4).

Fig. 6
figure 6

a. Percentage of patients recording Pulmojet and Turbohaler errors post-leaflet alone. b. Percentage of patients recording Pulmojet and Turbohaler errors post-leaflet and instructional video

Post hoc sensitivity analysis

The sensitivity analysis examining errors that were definitely serious (those that would definitely preclude adequate dose delivery to the lungs; see Additional file 1: Tables S1–S4) found that non-inferiority remained for both comparisons (Pulmojet vs. Diskus and Pulmojet vs. Turbohaler), post-leaflet alone and post-leaflet and instructional video (Table 4).

Table 4 Nurse-observed, definitely serious errors for Diskus vs. Pulmojet and Turbohaler vs. Pulmojet comparisons: post-patient information leaflet alone and post-leaflet and instructional video (post-hoc sensitivity analysis)

Post-leaflet alone, for the Pulmojet vs. Diskus comparison, superiority was no longer shown (Table 4). Overall, both preparation and inhalation errors were lower with Pulmojet than Diskus (Additional file 1: Tables S1 and S2). Post-leaflet and instructional video, superiority was shown. Preparation errors with Pulmojet were very low, while inhalation errors with Diskus remained high.

For the Pulmojet vs. Turbohaler comparison, superiority was shown both post-leaflet alone and post-leaflet and instructional video, with high preparation errors for Turbohaler in both cases (Table 4; Additional file 1: Tables S3 and S4).

Secondary endpoint: combined serious errors (nurse-observed and technology-assessed)

Table 5 shows superiority of Pulmojet use when technology-assessed errors were combined with nurse-observed errors.

Table 5 Combined serious errors (nurse-observed and technology-assessed) for Diskus vs. Pulmojet and Turbohaler vs. Pulmojet comparisons: post-patient information leaflet alone and post-leaflet and instructional video

Discussion

Results of the current study suggest that Pulmojet may be easier to learn to use correctly than either the Diskus or Turbohaler for current inhaler users who are switched to a new device. Patients with asthma and/or COPD were significantly less likely to make a nurse-observed serious error with Pulmojet than with Diskus or Turbohaler after receiving training by either the patient information leaflet alone or the leaflet and as-needed additional video instruction. Mastery of the inhalation technique is, therefore, more likely to be readily achieved with Pulmojet than either Diskus or Turbohaler. Designing inhaler devices to make them easier to use and teach is essential for improving long-term outcomes in asthma and COPD, so an important factor to consider when choosing a specific device is whether or not the patient is capable of using it correctly to achieve adequate drug delivery [25]. Furthermore, the ease of correct use of inhalers and patient preference for device can affect adherence with treatment and clinical outcomes [1, 5, 7, 1416, 2326].

Patients were not given verbal instructions alongside the patient information leaflet, so the use of the leaflet on its own mimicked common clinical practice (although sometimes patients may be verbally trained as well when prescribed a new device). We found that, for all inhalers tested, fewer serious errors were observed after patients read the patient information leaflet and watched an instructional video than after reading the leaflet alone. Our findings are in line with other reports that written or passive instructions alone, such as the patient information leaflets, are not sufficient to teach correct inhalation technique; and other tools, such as verbal instructions, multimedia educational materials, demonstrations, and practice sessions are needed to improve inhaler device technique [2535]. Crompton et al. [26] have also recommended that the teaching of correct inhalation techniques should be tailored to each patient’s needs and preferences; for example, multimedia methods may be more beneficial for younger patients, while one-to-one tuition is more suitable for elderly patients. The fact that errors in device technique remained after the instructional video suggests that instructional videos are useful but may not be adequate to ensure optimal device technique for all patients.

The comparator devices chosen for this study, the Diskus and the Turbohaler, are two of the most frequently prescribed multidose DPI devices worldwide. Previously reported incidence of serious errors ranges from 21–35 % with Diskus and 37–44 % with Turbohaler [1, 10]. The current device error data (study phase 1) showed a similar incidence for Diskus use (39 %) but greater error rates amongst the Turbohaler users (76 %). The high inhaler technique error rate amongst current pMDI users (92 %) was consistent with previous data [3].

The Pulmojet device has been designed to release its dose at a low minimum inspiratory flow. In-house measurements have identified that the dose is released from a Pulmojet at ≥25 L/min (unpublished data), which is below the recognised minimum inspiratory flow of the Turbohaler [3638] and the Diskus [39]. This ensures efficient de-aggregation of the dose during each inhalation so that drug particles most likely to be deposited into the airways are entrained in the inhaled airstream leaving the device. The Pulmojet inhaler has been designed with audio, visual, and sensory feedback mechanisms to indicate that an adequate inhalation has been performed, a feature appreciated by patients [40], whereas neither the Turbohaler nor Diskus provides any feedback to the patient that an adequate inspiratory flow has been achieved. Furthermore, because the dose is not released until a set inhalation flow is achieved, the Pulmojet can be held in any orientation during dose preparation.

Patients attending UK primary care practices were recruited for this study, and minimal exclusion criteria other than evidence of recent exacerbation or lower respiratory tract infection were applied to enable the study results to be generalisable to most patients with asthma and/or COPD receiving ICS or fixed-dose combination therapy in routine practice. Asthma, COPD and asthma-COPD were diagnoses made by the patients’ physicians according to their standard clinical practices, and we included both ICS and fixed-dose combinations as both are commonly prescribed for asthma and COPD in clinical practice [41]. Other strengths of this investigation include the randomised assignment to device training order, assessments made by trained independent nurses, and blinding of data analysts and statisticians. The practical importance of identifying superiority (rather than just non-inferiority) should also be recognised, as despite the ease of use of any one device compared with another, the overall management of chronic respiratory conditions is associated with a complex array of management issues, and hence it would be practically acceptable for a switch in device only if superiority were shown.

We acknowledge several limitations of the current research. Firstly, this was an open-label study that involved subjective assessment, and hence potential nurse bias, although efforts were made to standardise demonstration of devices and training in assessment of serious errors. Secondly, this study focused on self-training techniques (both the patient information leaflet and video are tools that the patient can employ at home); whereas, in practice, healthcare providers might incorporate their own educational style when training device-naïve patients for the first time (ie, the education may not be standardised in real life). Furthermore, although errors were defined by independent expert consensus, they were not validated as being serious. However, in the post-hoc sensitivity analysis restricted to errors that were definitely serious (ie, those that would definitely preclude adequate dose delivery to the lungs), the results remained largely the same. We included “inhalation is not forceful from the start” as a serious error based on the recommendations for DPI use of a recent European Respiratory Society/International Society for Aerosols in Medicine task force [42].

Another limitation is the fact that this study does not provide insight into maintenance of inhaler mastery or its impact on disease control. Learning to correctly handle a device is a continuous process and inhaler technique can decline over time [34], so it would be interesting to determine whether the superior results in inhaler technique observed with Pulmojet vs. Diskus and Turbohaler are maintained after a period of use and whether this is associated with better disease control. Moreover, patients considered as first-time users with regard to the Diskus or Turbohaler devices could potentially have used them in the past, more than 1 year before their inclusion in the study. In such cases, it is possible that any differences with the Pulmojet device would have been minimised or, conversely, that for patients switched at some time preceding the prior year from Diskus or Turbohaler because they could not handle it well, a comparison with Pulmojet would lead to a relatively favourable outcome for Pulmojet. However, we believe that patients using these devices previous to the 1 year were few if any. Finally, all enrolled patients were current inhaler users and hence our findings may not apply to patients prescribed an inhaler for the first time.

Conclusions

In patients with asthma and/or COPD who were given inhaler devices without proper training, fewer errors were made when using the Pulmojet for the first time when compared with Diskus and Turbohaler devices. These findings suggest that Pulmojet is a device that is easier to teach, easier to learn to use correctly, and easier to use. Thus, device mastery is more likely when using Pulmojet compared with Diskus or Turbohaler. The improvements after patients watched an instructional video suggest that videos could be useful for some individuals to complement inhaler technique training. In addition, the study design used here provides an adequate framework for future studies aimed at comparing the ease of effective training and use of other inhaler devices.

Notes

  1. Pulmojet® is a registered trademark in the property of Zentiva (Zentiva Group, a.s., Prague, Czech Republic)

  2. Turbohaler® is a registered trademark of the AstraZeneca group of companies

  3. Diskus® is a registered trademark of the GSK group of companies

Abbreviations

BMI:

body mass index

CI:

confidence interval

COPD:

chronic obstructive pulmonary disease

DPI:

dry powder inhaler

HI-TEC:

Handling Inhalers – Technique Error Comparison

ICS:

inhaled corticosteroid

NHS:

National Health Service

pMDI:

pressurised metered dose inhaler

SAS:

Statistical Analysis System

SD:

standard deviation

SPSS:

Statistical Package for the Social Sciences

UK:

United Kingdom

References

  1. Melani AS, Bonavia M, Cilenti V, Cinti C, Lodi M, Martucci P, et al. Inhaler mishandling remains common in real life and is associated with reduced disease control. Respir Med. 2011;105:930–8.

    Article  PubMed  Google Scholar 

  2. Molimard M, Raherison C, Lignot S, Depont F, Abouelfath A, Moore N. Assessment of handling of inhaler devices in real life: an observational study in 3811 patients in primary care. J Aerosol Med. 2003;16:249–54.

    Article  CAS  PubMed  Google Scholar 

  3. Al-Showair RA, Pearson SB, Chrystyn H. The potential of a 2Tone Trainer to help patients use their metered-dose inhalers. Chest. 2007;131:1776–82.

    Article  PubMed  Google Scholar 

  4. Rootmensen GN, van Keimpema AR, Jansen HM, de Haan RJ. Predictors of incorrect inhalation technique in patients with asthma or COPD: a study using a validated videotaped scoring method. J Aerosol Med Pulm Drug Deliv. 2010;23:323–8.

    Article  PubMed  Google Scholar 

  5. Papi A, Haughney J, Virchow JC, Roche N, Palkonen S, Price D. Inhaler devices for asthma: a call for action in a neglected field. Eur Respir J. 2011;37:982–5.

    Article  CAS  PubMed  Google Scholar 

  6. Price D, Roche N, Christian Virchow J, Burden A, Ali M, Chisholm A, et al. Device type and real-world effectiveness of asthma combination therapy: An observational study. Respir Med. 2011;105:1457–66.

    Article  PubMed  Google Scholar 

  7. Giraud V, Allaert FA, Roche N. Inhaler technique and asthma: feasability and acceptability of training by pharmacists. Respir Med. 2011;105:1815–22.

    Article  PubMed  Google Scholar 

  8. Al-Jahdali H, Ahmed A, Al-Harbi A, Khan M, Baharoon S, Bin Salih S, et al. Improper inhaler technique is associated with poor asthma control and frequent emergency department visits. Allergy Asthma Clin Immunol. 2013;9:8.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Yildiz F. Importance of inhaler device use status in the control of asthma in adults: the asthma inhaler treatment study. Respir Care. 2014;59:223–30.

    Article  PubMed  Google Scholar 

  10. Molimard M, Le Gros V. Impact of patient-related factors on asthma control. J Asthma. 2008;45:109–13.

    Article  PubMed  Google Scholar 

  11. Chrystyn H, Price D. Not all asthma inhalers are the same: factors to consider when prescribing an inhaler. Prim Care Respir J. 2009;18:243–9.

    Article  PubMed  Google Scholar 

  12. Price D, Thomas M. Breaking new ground: challenging existing asthma guidelines. BMC Pulm Med. 2006;6 Suppl 1:S6.

    Article  PubMed  Google Scholar 

  13. Haughney J, Price D, Kaplan A, Chrystyn H, Horne R, May N, et al. Achieving asthma control in practice: understanding the reasons for poor control. Respir Med. 2008;102:1681–93.

    Article  PubMed  Google Scholar 

  14. Virchow JC, Crompton GK, Dal Negro R, Pedersen S, Magnan A, Seidenberg J, et al. Importance of inhaler devices in the management of airway disease. Respir Med. 2008;102:10–9.

    Article  CAS  PubMed  Google Scholar 

  15. Lavorini F, Magnan A, Dubus JC, Voshaar T, Corbetta L, Broeders M, et al. Effect of incorrect use of dry powder inhalers on management of patients with asthma and COPD. Respir Med. 2008;102:593–604.

    Article  PubMed  Google Scholar 

  16. Schulte M, Osseiran K, Betz R, Wencker M, Brand P, Meyer T, et al. Handling of and preferences for available dry powder inhaler systems by patients with asthma and COPD. J Aerosol Med Pulm Drug Deliv. 2008;21:321–8.

    Article  CAS  PubMed  Google Scholar 

  17. Rau JL. Practical problems with aerosol therapy in COPD. Respir Care. 2006;51:158–72.

    PubMed  Google Scholar 

  18. Haughney J, Price D, Barnes NC, Virchow JC, Roche N, Chrystyn H. Choosing inhaler devices for people with asthma: current knowledge and outstanding research needs. Respir Med. 2010;104:1237–45.

    Article  PubMed  Google Scholar 

  19. Global Strategy for Asthma Management and Prevention, revised 2015. Global Initiative for Asthma (GINA). www.ginasthma.org. Accessed 12 May 2015.

  20. Dekhuijzen PN, Vincken W, Virchow JC, Roche N, Agusti A, Lavorini F, et al. Prescription of inhalers in asthma and COPD: towards a rational, rapid and effective approach. Respir Med. 2013;107:1817–21.

    Article  CAS  PubMed  Google Scholar 

  21. Price D, Bosnic-Anticevich S, Briggs A, Chrystyn H, Rand C, Scheuch G, et al. Inhaler competence in asthma: common errors, barriers to use and recommended solutions. Respir Med. 2013;107:37–46.

    Article  CAS  PubMed  Google Scholar 

  22. Mehuys E, Boussery K, Adriaens E, Van Bortel L, De Bolle L, Van Tongelen I, et al. COPD management in primary care: an observational, community pharmacy-based study. Ann Pharmacother. 2010;44:257–66.

    Article  PubMed  Google Scholar 

  23. Giraud V, Roche N. Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability. Eur Respir J. 2002;19:246–51.

    Article  CAS  PubMed  Google Scholar 

  24. Azouz W, Chetcuti P, Hosker HS, Saralaya D, Stephenson J, Chrystyn H. The inhalation characteristics of patients when they use different dry powder inhalers. J Aerosol Med Pulm Drug Deliv. 2015;28:35–42.

    Article  PubMed  Google Scholar 

  25. Blaiss MS. Part II: Inhaler technique and adherence to therapy. Curr Med Res Opin. 2007;23 Suppl 3:S13–20.

    Article  PubMed  Google Scholar 

  26. Crompton GK, Barnes PJ, Broeders M, Corrigan C, Corbetta L, Dekhuijzen R, et al. The need to improve inhalation technique in Europe: a report from the Aerosol Drug Management Improvement Team. Respir Med. 2006;100:1479–94.

    Article  CAS  PubMed  Google Scholar 

  27. Giraud V, Allaert FA, Magnan A. A prospective observational study of patient training in use of the autohaler inhaler device: the Sirocco study. Eur Rev Med Pharmacol Sci. 2011;15:563–70.

    CAS  PubMed  Google Scholar 

  28. Crane MA, Jenkins CR, Goeman DP, Douglass JA. Inhaler device technique can be improved in older adults through tailored education: findings from a randomised controlled trial. NPJ Prim Care Respir Med. 2014;24:14034.

    Article  PubMed  PubMed Central  Google Scholar 

  29. Basheti IA, Armour CL, Bosnic-Anticevich SZ, Reddel HK. Evaluation of a novel educational strategy, including inhaler-based reminder labels, to improve asthma inhaler technique. Patient Educ Couns. 2008;72:26–33.

    Article  PubMed  Google Scholar 

  30. Steier J, Trammer T, Cloes RM, Petro W. Optical feedback training of inhalation with Autohaler and Turbuhaler in COPD patients. Lung. 2003;181:183–92.

    Article  CAS  PubMed  Google Scholar 

  31. van der Palen J, Klein JJ, Kerkhoff AH, van Herwaarden CL, Seydel ER. Evaluation of the long-term effectiveness of three instruction modes for inhaling medicines. Patient Educ Couns. 1997;32:S87–95.

    Article  PubMed  Google Scholar 

  32. Verver S, Poelman M, Bogels A, Chisholm SL, Dekker FW. Effects of instruction by practice assistants on inhaler technique and respiratory symptoms of patients. A controlled randomized videotaped intervention study. Fam Pract. 1996;13:35–40.

    Article  CAS  PubMed  Google Scholar 

  33. McElnay JC, Scott MG, Armstrong AP, Stanford CF. Audiovisual demonstration for patient counselling in the use of pressurised aerosol bronchodilator inhalers. J Clin Pharm Ther. 1989;14:135–44.

    Article  CAS  PubMed  Google Scholar 

  34. Bosnic-Anticevich SZ, Sinha H, So S, Reddel HK. Metered-dose inhaler technique: the effect of two educational interventions delivered in community pharmacy over time. J Asthma. 2010;47:251–6.

    Article  CAS  PubMed  Google Scholar 

  35. Aydemir Y. Assessment of the factors affecting the failure to use inhaler devices before and after training. Respir Med. 2015;109:451–8.

    Article  PubMed  Google Scholar 

  36. Palander A, Mattila T, Karhu M, Muttonen E. In vitro comparison of three salbutamol-containing multidose dry powder inhalers: Buventol Easyhaler(R), Inspiryl Turbuhaler(R) and Ventoline Diskus(R). Clin Drug Investig. 2000;20:25–33.

    Article  CAS  Google Scholar 

  37. Newman SP, Morén F, Trofast E, Talaee N, Clarke SW. Terbutaline sulphate Turbuhaler: effect of inhaled flow rate on drug deposition and efficacy. Int J Pharm. 1991;74:209–13.

    Article  CAS  Google Scholar 

  38. Borgstrom L, Bondesson E, Moren F, Trofast E, Newman SP. Lung deposition of budesonide inhaled via Turbuhaler: a comparison with terbutaline sulphate in normal subjects. Eur Respir J. 1994;7:69–73.

    Article  CAS  PubMed  Google Scholar 

  39. Nielsen KG, Auk IL, Bojsen K, Ifversen M, Klug B, Bisgaard H. Clinical effect of Diskus dry-powder inhaler at low and high inspiratory flow-rates in asthmatic children. Eur Respir J. 1998;11:350–4.

    Article  CAS  PubMed  Google Scholar 

  40. Moller M, Fritsche D, Rivera D, Libertus H. Improvement of asthma therapy by a novel budesonide multidose dry powder inhaler. Arzneimittelforschung. 2003;53:562–7.

    PubMed  Google Scholar 

  41. Price D, West D, Brusselle G, Gruffydd-Jones K, Jones R, Miravitlles M, et al. Management of COPD in the UK primary-care setting: an analysis of real-life prescribing patterns. Int J Chron Obstruct Pulmon Dis. 2014;9:889–90.

    Article  PubMed  PubMed Central  Google Scholar 

  42. Laube BL, Janssens HM, de Jongh FH, Devadason SG, Dhand R, Diot P, et al. What the pulmonary specialist should know about the new inhalation therapies. Eur Respir J. 2011;37:1308–31.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgments

We thank Sandra Kreuzaler, Clinical Studies Lead, and Anu Kemppinen for their assistance in coordinating the study. We are grateful to the Principal Investigators and staff at the study sites (listed in Additional file 3) for their contributions to the study. We acknowledge Adam Brady for development and preparation of the randomisation programme and study electronic case report form. Medical writing and editorial assistance was provided by Elizabeth V. Hillyer, DVM, ELS, Consultant to Research in Real-Life, and by Delia Randall, PhD, supported by Research in Real-Life.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to David B. Price.

Additional information

Competing interests

The study was funded by Zentiva, Prague, Czech Republic, and was performed in compliance with Good Clinical Practice. Zentiva played no role in the conduct of the study. Henry Chrystyn has no shares in any pharmaceutical companies. He has received sponsorship to carry out studies, together with some consultant agreements and honoraria for presentation, from several pharmaceutical companies that market inhaled products. These include Almirall, AstraZeneca, Boehringer Ingelheim, Chiesi, GlaxoSmithKline, Innovata Biomed, Meda, Napp Pharmaceuticals, Mundipharma, NorPharma, Norvartis, Orion, Sanofi, Teva, Truddell Medical International, UCB and Zentiva. Research sponsorship has also been received from grant awarding bodies (EPSRC and MRC). He owns 50 % of Inhalation Consultancy Ltd.

David B Price has Board Membership with Aerocrine, Almirall, Amgen, AstraZeneca, Boehringer Ingelheim, Chiesi, Meda, Mundipharma, Napp, Novartis, and Teva. Consultancy: Almirall, Amgen, AstraZeneca, Boehringer Ingelheim, Chiesi, GlaxoSmithKline, Meda, Mundipharma, Napp, Novartis, Pfizer, Teva, and Zentiva; Grants/Grants Pending with UK National Health Service, British Lung Foundation, Aerocrine, AstraZeneca, Boehringer Ingelheim, Chiesi, Eli Lilly, GlaxoSmithKline, Meda, Merck, Mundipharma, Novartis, Orion, Pfizer, Respiratory Effectiveness Group, Takeda, Teva, and Zentiva; Payments for lectures/speaking: Almirall, AstraZeneca, Boehringer Ingelheim, Chiesi, Cipla, GlaxoSmithKline, Kyorin, Meda, Merck, Mundipharma, Novartis, Pfizer, SkyePharma, Takeda, and Teva; Payment for manuscript preparation: Mundipharma and Teva; Patents (planned, pending or issued): AKL Ltd.; Payment for the development of educational materials: GlaxoSmithKline, Novartis; Stock/Stock options: Shares in AKL Ltd which produces phytopharmaceuticals and owns 80 % of Research in Real Life Ltd and its subsidiary social enterprise Optimum Patient Care; received Payment for travel/accommodations/meeting expenses from Aerocrine, Boehringer Ingelheim, Mundipharma, Napp, Novartis, and Teva; Funding for patient enrolment or completion of research: Almirall, Chiesi, Teva, and Zentiva; Peer reviewer for grant committees: Medical Research Council (2014), Efficacy and Mechanism Evaluation programme (2012), HTA (2014); and Received unrestricted funding for investigator-initiated studies from Aerocrine, AKL Ltd, Almirall, Boehringer Ingelheim, Chiesi, Meda, Mundipharma, Napp, Novartis, Orion, Takeda, Teva, and Zentiva.

Mathieu Molimard has Board Membership and Consultancy with Almirall, AstraZeneca, BMS, GlaxoSmithKline, Lundbeck, Mundipharma, Novartis Pharma, Otsuka, Pfizer, Stallergen, Zentiva; received payment for travel/accommodations/meeting expenses from Novartis Pharma.

John Haughney has received reimbursements for attending symposia, fees for speaking, organising educational events, funds for research or fees for consulting from Almirall, AstraZeneca, Boehringer Ingelheim, GlaxoSmithKline, Merck Sharp & Dohme, Mundipharma, Novartis and Teva.

Sinthia Bosnic-Anticevich has received reimbursements for attending meetings, fees for speaking, or consultancy from Mundipharma and Teva.

Federico Lavorini has received reimbursements for attending meetings, fees for speaking, or consultancy from: AstraZeneca, Boehringer Ingelheim, Chiesi, Mundipharma, GSK and Zentiva.

John Efthimiou has received fees for consultancy or speaking from GlaxoSmithKline, Oxagen, Sanofi, 3 M Pharmaceuticals, Vectura, and Zentiva.

Dawn Shan, Erika Sims, Anne Burden, and Catherine Hutton are employees of Research in Real Life, which conducted this study and which has conducted paid research in respiratory disease on behalf of the following other organizations in the past 5 years: Aerocrine, AKL Ltd, Almirall, AstraZeneca, Boehringer Ingelheim, Chiesi, GlaxoSmithKline, Meda, Mundipharma, Napp, Novartis, Orion, Takeda, Teva, and Zentiva.

Nicolas Roche has received over the past 3 years (i) fees for speaking, organising education, participation in advisory boards or consulting from 3M, Aerocrine, Almirall, AstraZeneca, Boehringer Ingelheim, Chiesi, Cipla, GlaxoSmithKline, MSD-Chibret, Mundipharma, Novartis, Pfizer, Sandoz, Sanofi, Stallergenes, Takeda, Teva; (ii) research grants from Novartis, Boehringer Ingelheim and Pfizer.

Authors’ contributions

HC, DBP, and ES led the study design process; DS is responsible for data collection; AB conducted the analyses. HC, DBP, MM, JH, SB-A, FL, JE, DS, ES, AB, CH, NR participated in the interpretation of the data, drafting and critical revision of the manuscript, and decision to submit the manuscript for publication. All authors read and approved the final manuscript.

Additional files

Additional file 1:

Provides a list of predefined errors and percentages of patients making errors with each inhaler device. (PDF 101 kb)

Additional file 2:

Provides details of sample size determination. (PDF 288 kb)

Additional file 3:

Provides a list of local Principal Investigators responsible for the conduct of the study at general practice sites participating in the study. (PDF 24 kb)

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chrystyn, H., Price, D.B., Molimard, M. et al. Comparison of serious inhaler technique errors made by device-naïve patients using three different dry powder inhalers: a randomised, crossover, open-label study. BMC Pulm Med 16, 12 (2016). https://doi.org/10.1186/s12890-016-0169-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12890-016-0169-5

Keywords